Giant GP7170-4000 User Manual

Page 3

Advertising
background image

3

U.S. .............................. Metric

Volume ................................................................. 84.5 GPM ..................... 320 LPM
Discharge Pressure ............................................. 1450 PSI ....................... 100 bar
Speed .......................................................................................................... Up to 700 RPM
Inlet Pressure .............................................................................................. Up to 90 PSI

2

(10 bar)

Plunger Diameter ................................................. 2.48” ............................. 63 mm
Plunger Stroke ..................................................... 2.05” ............................. 52mm
Crankshaft Diameter ........................................... 2.05” ............................. 52mm
Key Width ................................................................................................... 14mm
Crankshaft Mounting .................................................................................. Either side
Shaft Rotation ................................................................................ Top of pulley towards manifold
Temperature of Pumped Fluids ............................ 140

o

F ........................... 60

o

C

Inlet Ports ................................................................................................... (2) 1 1/4" NPT
Discharge Ports .......................................................................................... (2) 3/4" NPT
Weight .................................................................. 374 lbs. ......................... 170 kg
Crankcase Oil Capacity ....................................... 1.6 Gal. ......................... 6.0 liters
Fluid End Material ....................................................................................... Stainless Steel

Specifications

Model GP7170-4000

HORSEPOWER RATINGS:

The rating shown are the power require-
ments for the pump. Gas engine power
outputs must be approximately twice the
pump power requirements shown above.

We recommend a 1.1 service factor be specified
when selecting an electric motor as the power
source.

To compute specific pump horsepower requirements,
use the following formula:

GPM X PSI
1400

Consult the factory for special requirements that must be met if the pump is to
operate beyond one or more of the limits specified above.

= hp

PUMP

PULLEY

MOTOR

PULLEY

RPM GPM 500 PSI

750 PSI 1000 PSI 1500 PSI

12.75

7.00

300

36.0

12.9

19.3

25.7

38.6

12.75

9.20

400

49.0

17.5

26.3

35.0

52.5

12.75

11.45

500

60.0

21.4

32.1

42.9

64.3

12.75

12.75

700

84.5

30.2

45.3

60.4

90.5

GP7170 PULLEY SELECTION & HORSEPOWER

REQUIREMENTS

Advertising