110v operation – Grizzly G0573 User Manual

Page 8

Advertising
background image

-6-

G0573 Two Speed Floor Air Filter

Serious personal injury could occur if you

connect the machine to the power source

before you have completed the set up pro-

cess. DO NOT connect the machine to the

power source until instructed to do so.

110V Operation

Amperage Draw

The 1

3

4

HP motor on the Model G0573 will draw

the following amps:

Motor Load ....................................... 12-14 Amps

Circuit Breaker Requirements

Install your machine on a dedicated circuit to
reduce the possibility of tripping the circuit break-
er. If the circuit breaker frequently trips, have the
circuit inspected by a qualified electrician. Never
use a larger circuit breaker than stated below, or
you will increase the risk of fire.

Circuit Breaker .........................................15 Amp

Plug Type

The Model G0573 is supplied with an inverted-
type 5-15 plug. You must insert an extension cord
receptacle over the inverted plug and then insert
the male part of the extension cord into a 5-15
wall receptacle.

This machine must have a ground prong in

the plug to help ensure that it is grounded.

DO NOT remove ground prong from plug

to fit into a two-pronged outlet! If the plug

will not fit the outlet, have the proper outlet

installed by a qualified electrician.

Extension Cords

Make sure the cord is rated Standard Service
(grade S) or better.

The extension cord must contain a ground
wire and plug pin.

Use at least a 16 gauge cord.

DO NOT use a cord longer than 50 feet!

.

SECTION 2: CIRCUIT REQUIREMENTS

Electrocution or fire could

result if this machine is

not grounded correctly or

if your electrical configu-

ration does not comply

with local and state codes.

Ensure compliance by

checking with a qualified

electrician!