Rough-In Dimensions

Dryer MUST be exhausted outside (outdoors, not
beneath the mobile home) using metal ducting
that will not support combustion. Metal ducting
must be 4

″ (10.16 cm) in diameter with no

obstructions. Rigid metal duct is preferred.

If dryer is exhausted through the floor, the
exhaust system MUST NOT terminate beneath the
mobile home. Termination MUST be securely
fastened to the mobile home structure.

When installing a dryer into a mobile home,
a provision must be made for outside make-up
air. Provide an opening with a free area of at
least 25 square inches for introduction of outside
air into the dryer room.

Gas dryers MUST be fastened to the floor
using Mobile Home Installation Kit
Pub. No. 14-D346-33.

See the Exhaust System Requirements section
for other important venting information.

Installation MUST conform to current
Manufactured Home Construction & Safety
Standard (which is a Federal Regulation Title
24 CFR—Part 32–80) or, when such standard is
not applicable, with American National Standard
for Mobile Homes, ANSI/NFPA No. 501B.

The dryer is designed under ANSI Z 21.5.1

for HOME USE only.

6

5

4

3

2

1

Mobile Home Installation

26 7/8

(68.3 cm)

47 1/2

(120.7 cm)

43 5/8

(110.7 cm)

2 9/16

(6.5 cm)

13 1/2

(34.4 cm)

36

(91.5 cm)

Door open

90˚

4 3/8

(11.1 cm)

Optional

vent knockout

27

(68.6 cm)

Electrical connection

3/8

″ (0.96 cm) Dia.

gas pipe

1

″ (2.54 cm)

3 3/4

(9.5 cm)

3 3/4

(9.5 cm)

REAR VIEW

SIDE VIEW

Correct

Incorrect

Do

Do

Do

Don’t

Don’t

Don’t

Servicing – Consideration must be given to provide adequate clearances for installation and servicing.