Retorquing the head bolts – Generac 190/220 User Manual

Page 12

Advertising
background image

RETORQUING THE HEAD BOLTS

After the first 50 hours of operation, retorque the head bolts.

NOTE: Only perform this adjustment after the first 50 hours of

operation. The head bolts will need no further adjustment.

1.

Remove the four (4) screws from the rocker cover
(see Figure 10).

2.

Remove the rocker cover and rocker cover gasket.

3.

Torque the bolts to 4.0 kg-m. (22 ft-lb).

4.

Torque the bolts in the following sequence: A, B, C, D, E
(star pattern). See Figure 12.

Figure 12 — Tightening Sequence

E

B

D

C

A

G

Geen

neerraacc G

GN

N--119900//222200 E

En

ng

giin

nee

— 12 —

MAINTENANCE SCHEDULE

Every 8 Hours or

25 Hours or Every

50 Hours or Every

100 Hours or Every

MAINTENANCE OPERATION

or Daily

Season

Season

Season

Check Oil Level

X

Change Oil

See Note 1

Change Oil Filter (if so equipped)

See Note 1

Service Air Filter

Foam Pre-Filter

Paper Filter (Note 2)

Replace or Clean Spark Plug

X

Clean Spark Arrestor Screen

X

Adjust Valve Clearance

X

Retorque Head Bolts

See Note 3

NOTE 1: Change oil and filter after first 8 hours of operation and then every 50 hours thereafter. Change sooner when operating under heavy load or in
dusty or dirty environment or in high ambient temperature.

NOTE 2: Clean more often when operating under dirty or dusty conditions.

NOTE 3: Perform this task ONLY after first 50 hours of operation. Head bolts will NOT need further retorquing.

Advertising