When Your Refrigerator Is First Plugged In

How the Monitor and Diagnostic System Works

All panel lights come on for five seconds,

a beep sounds, and lights go off except as

follows:

PF

flashes in the display. Touch SYSTEM

CHECK-RESET

to erase it.

NORMAL

glows.

WARM TEMP

glows until the refrigerator

cools down. It goes off when proper food-

keeping temperature is reached.

Door alarm beeper is activated and DOOR
ALARM

glows.

CRUSHED ICE

glows.

DOOR OPEN

flashes if either door is open,

goes out when doors are shut.

Night light in ice and water dispenser

is off.

How to Set the Door Alarm

To set the alarm press DOOR ALARM until it

glows.
The control beeps if either door is open for

more than 30 seconds.
The light goes out and the beeping stops

when you close the door.

DOOR ALARM

ON/OFF

Why the WARM TEMP Light Glows

At first, it’s probably because your newly-

installed refrigerator hasn’t completely

cooled down yet. Wait a few hours for it to

cool, and then the light will go out.
From then on, WARM TEMP will glow

whenever temperatures inside get too high

for proper food storage. If this happens,

open the doors only when absolutely

necessary, and close them as quickly as

possible.

As soon as inside temperatures return to

normal, the light goes out.
If WARM TEMP reappears and stays on for

longer than 4 hours, call for service.

WARM

TEMP

The diagnostic code flashes and the control

beeps when something starts to go wrong.
If more than one coded function requires

attention at the same time, the one with the

highest priority will be displayed first.

Pressing SYSTEM CHECK-RESET will erase

two codes immediately—PF and CI. The dE

and FF codes can only be erased by pressing
SYSTEM CHECK-RESET

after the condition

that caused the code to flash has been

corrected.

SYSTEM CHECK-RESET

will also evaluate

all other coded functions. If NORMAL is

lit during the displaying of a code, that

function is operating properly.

SYSTEM

CHECK

RESET

Advertising