INSTALLATION INSTRUCTIONS

• Position the back and side cast firebricks on the grate

behind the raised ribs, See Diagram 30

30

• Slide the ashpan (G) under the grate

•Hook the front bars (H) onto the fireplace and slide the

ashpan cover (F) into position below them

6. FITTING AND REMOVAL OF

FLUE DAMPER

6.1 To maintain efficient combustion, the appliance is fitted

with a Flue Damper System. See Diagram 31

31

6.2 Allow the appliance to cool fully before removing Flue

Damper.

6.3 To remove the damper system, first remove the fuel kit

and Frame if fitted from the appliance to give access to the

firebox, See section 2-3

6.4 Remove the Pivot Bolts (both sides of the firebox) while

holding the Damper in position. This will allow the Damper

to drop down for removal. Note the position of washers on

the Pivot Bolts

32

PR8094

6.5 The replacement of the system is the reverse of the previous

operations.

6.6 It is important to remove and clean the Flue Damper

system to ensure the flue ways are clear of soot and debris

to ensure the safe and efficient operation of the appliance.

The frequency of cleaning will depend on the appliance

operating conditions.

6.7 The Flue Damper system is designed to give safe and

efficient operation of the appliance. Replace any damaged

baffles immediately.

6.8 Do not modify the Flue Damper.

7. DAMPER ARM ADJUSTMENT

7.1 Set the Damper Arm, Diagram 26

If the damper arm is either too loose or too tight in

operation adjust by the following method:

• Ensure both pivot bolts are tight

• Slacken the two tension bolts

• Adjust the adjusting bolt

• Re-tighten the two tension bolts

26