G1028z wiring, G1029 wiring – Grizzly G1028Z/G1029 User Manual

Page 7

Advertising
background image

G1028Z/G1029 Dust Collector

-5-

SECTION 2: CIRCUIT REQUIREMENTS

G1028Z Wiring

The G1028Z Dust Collector is pre-wired for 110V,
but can be rewired for 220V. Refer to the wiring
diagram included with this manual for instruction.
Do not attempt to rewire the motor if the diagram
is missing. Contact the appropriate service center
for more information.

A plug is not provided with the G1028Z. It will be
necessary to purchase a standard 110V plug from
your local hardware store. If you are rewiring for
220V, see

Figure 1

for the recommended 220V

receptacle.

Circuit Breaker:

The 1

1

2

H.P. motor will draw

roughly 18 amps at 110V or 9 amps at 220V. We
recommend a using 20 amp circuit breaker for
110V or 220V operation. Circuit breakers rated
higher will not adequately protect the circuit. If you
are using a fuse, we recommend a 30 amp slow
blow for 110V or 220V operation. Fuses rated
higher will not adequately protect the circuit.

G1029 Wiring

The G1029 Dust Collector is pre-wired for 220V.

A plug is not provided with the G1029. Refer to

Figure 1

for recommended 220V receptacle.

Circuit Breaker:

The 2 H.P. motor will draw

roughly 12 amps @ 220V. We recommend using
a 20 amp circuit breaker. Circuit breakers rated
higher will not adequately protect the motor. If you
are using a fuse, we recommend 30 amp slow
blow 220V service. Fuses rated higher will not
adequately protect the motor.

Figure 1.

Recommended 220V receptacle.

Advertising