Specifications model p211 – Giant P207 User Manual

Page 9

Advertising
background image

P211 HORSEPOWER REQUIREMENTS

RPM GPM 1000 PSI 1500 PSI 2000 PSI 2500 PSI*

500

0.60

0.4

0.6

0.8

1.0

1000 1.20

0.8

1.2

1.7

2.1

1750 2.10

1.4

2.2

2.9

3.6

3000 3.30

2.3

3.4

4.6

5.7

3200 3.52

2.4

3.6

4.9

6.1

3450 3.80

2.6

3.9

5.2

6.5

9

Specifications

Model P211

Consult the factory for special requirements that must be met if the pump is
to operate beyond one or more of the limits specified above.

NOTE:

In order to drive the pump from the side opposite the present shaft extension, simply remove

the valve casing from the crankcase and rotate the pumps 180 degrees to the desired position. Be
certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o'clock
position. Exchange the oil fill and the oil drain plugs, also. Refer to the repair instructions as
necessary for the proper assembly sequence.

*Intermittent duty only

HORSEPOWER RATINGS:
The rating shown are the power

requirements for the pump. Gas
engine power outputs must be
approximately twice the pump
power requirements shown above.

We recommend a 1.15 service factor
be specified when selecting an
electricmotor as the power source.
To compute specific pump horse
power requirements, use the
following formula:

HP = (GPM X PSI) / 1450

1750 RPM

+

...................................................................................................

U. .S.

Metric

Flow (Continuous) @ 2000 PSI (140 Bar) .......... 2.1 GPM ....................... 7.9 L/min
Flow (Intermittent) @ 2500 PSI (175 Bar) ......... 2.1 GPM ....................... 7.9 L/min
3450 RPM

+

Flow (Continuous) @ 2000 PSI (140 Bar) .......... 3.8 GPM ....................... 14.4 L/min
Flow (Intermittent) @ 2000 PSI (140 Bar) ......... 3.8 GPM ....................... 14.4 L/min
Maximum Inlet Pressure ..................................... 145 PSI ......................... 10 Bar
Plunger Diameter ................................................. 0.47” ............................. 12 mm
Stroke ................................................................... 0.56” ............................. 14.2 mm
Max. Temperature of Pumped Fluids .................. 160

o

F ............................ 70

o

C

Inlet Ports .................................................................................................... (2) 1/2" BSP
Discharge Ports ........................................................................................... (2) 3/8" BSP
Shaft Rotation ...................................................... Top of Pulley Towards Fluid End
Crankshaft Diameter ............................................ 0.98” ............................. 24 mm
Key Width ........................................................... 0.31” ............................. 8 mm
Shaft Mounting .................................................... Right Side Facing Manifold
Weight ................................................................. 11.7 lbs. ........................ 5.3 Kg
Crankcase Oil Capacity ....................................... 7.5 fl.oz. ....................... 0.22 Liters
Extended Crankcase Oil Capacity ....................... 9.0 fl.oz. ....................... 0.27 Liters
Volumetric Efficiency @ 1750 RPM ......................................................... 0.94
Volumetric Efficiency @ 3450 RPM ......................................................... 0.87
Mechanical Efficiency @ 3450 RPM ......................................................... 0.86

+

Positive inlet pressure required

Advertising
This manual is related to the following products: