110v operation – Grizzly G0463 User Manual

Page 12

Advertising
background image

-10-

G0463 Small Mill/Drill

Figure 2. A 5-15 plug and receptacle.

Serious personal injury could occur if you

connect the machine to the power source

before you have completed the set up pro-

cess. DO NOT connect the machine to the

power source until instructed to do so.

110V Operation

Amperage Draw

The Model G0463 motor draws the following
amps under maximum load:

Motor Draw ..............................................7 Amps

Circuit Recommendations

We recommend connecting this machine to a
dedicated circuit with a verified ground, using the
circuit breaker size given below. Never replace a
circuit breaker with one of higher amperage with-
out consulting a qualified electrician to ensure
compliance with wiring codes.

If you are unsure

about the wiring codes in your area or you

plan to connect your machine to a shared cir-

cuit, you may create a fire hazard—consult a

qualified electrician to reduce this risk.

Circuit Breaker .......................................10 Amps

Plug/Receptacle Type

Included Plug Type ........................... NEMA 5-15

This machine must have a ground prong in

the plug to help ensure that it is grounded.

DO NOT remove ground prong from plug

to fit into a two-pronged outlet! If the plug

will not fit the outlet, have the proper outlet

installed by a qualified electrician.

Extension Cords

We do not recommend the use of extension
cords, if you find it absolutely necessary:

Use at least a 16 gauge cord that does not
exceed 50 feet in length!

The extension cord must also contain a
ground wire and plug pin.

A qualified electrician MUST size cords over
50 feet long to prevent motor damage.

SECTION 2: CIRCUIT REQUIREMENTS

Electrocution or fire could

result if this machine is

not grounded correctly or

if your electrical configu-

ration does not comply

with local and state codes.

Ensure compliance by

checking with a qualified

electrician!

Advertising