Specification Revised 1/04

110104

ZISS360NRSS – GE Monogram 36" Stainless Steel Built-In Side-by-Side

Refrigerator with Automatic Icemaker and Water Filter

Water and Electrical Locations

The opening must be prepared with the electrical and water

supply located as shown.
The cutout depth must be 24".

The refrigerator will project forward, slightly beyond adjacent

cabinetry, depending on your installation.
The cutout depth beneath a soffit:

When installed beneath a soffit, the soffit cannot exceed the

24" installation depth shown. The top case trim overlaps the

bottom of the soffit.
Frameless cabinets:

The case trim overlaps cabinets at the top and sides.

Therefore, frameless cabinets may require filler strips to

prevent interference with cabinet door swing. The opening

must allow for filler strips.
Additional Specifications

• A 115 volt 60Hz., 15 or 20 amp power supply is required.

An individual properly grounded branch circuit or circuit

breaker is recommended. Install a properly grounded

3-prong electrical receptacle recessed into the back wall.

Electrical must be located on rear wall as shown.

Note: GFI (ground fault interrupter) is not recommended.
• Water line can enter the opening through the floor or back

wall. The water line should be 1/4" O.D. copper tubing or

GE SmartConnect

kit between the cold water line and

water connection location, long enough to extend to the

front of the refrigerator. Installation of an easily accessible

shut off valve in the water line is recommended.

The Installation Space

Product Clearances

These refrigerators are equipped with a 2 position door stop.

The factory set 130° door swing can be adjusted to 90° if

clearance to adjacent cabinets or walls is restricted.

* Shipping height.

The refrigerator

can be adjusted to

fit into a cutout that

is 83-1/2” min. to

84-1/2” max. height

Note that the top

case trim at the

front is 1/2” higher

and will overlap

upper cabinetry or

soffit. Use leveling

legs and wheels for

a maximum 1" height

adjustment.

194Dia26

15"

13"

Allow minimum clearances for freezer door and fresh food

door for a full 130° door swing and to allow for pan removal.
4" minimum clearance is required when door swing is adjusted

to 90°. If the 90° door stop position is used, pan access is

maintained, but pan removal is restricted.
Installation Information: Before installing, consult

installation instructions packed with product, or available

at Monogram.com, for current dimensional data.

R

Listed by

Underwriters

Laboratories

As an ENERGY STAR

®

partner, GE has determined

that this product meets the

ENERGY STAR guidelines

for energy efficiency.

For answers to your Monogram,

®

GE Profile

or

GE

®

appliance questions, visit our website at

GEAppliances.com or call

GE Answer Center

®

service, 800.626.2000.

*84" From

Floor to

Top Frame

36"

Frame to Frame

35"

Case Width

*83-1/2"

at

Rear

25-3/4"

27-3/4"

including

handle

35-1/2"

6"

5"

Electrical

Area

84-1/2" max

83-1/2" min

Finished

Opening

75" From Floor

to Bottom

of Electrical

Area

24"

5"

5"

3-1/2"

Water Supply

3-1/2"

36" Models 12"

194Dia4

23-7/8"

Behind

Frame

20-5/8

4" Min.

to Wall

Advertising