Plug-type circuit breaker amperage draw – Grizzly Model G0550 User Manual

Page 8

Advertising
background image

-6-

G0550/G0551 15" Planer

The Model G0550/G0551 motor is wired to oper-
ate at 220V only. The planer motors draw the fol-
lowing amperage:

Amperage Draw
G0550 2 HP ..........................................12 Amps
G0551 3 HP ..........................................18 Amps

Use the following guidelines when choosing a cir-
cuit breaker (circuit breakers rated any higher are
not adequate to protect the circuit):

Circuit Breaker
G0550 ........................................15 Amp, 2 Pole
G0551 ........................................20 Amp, 2 Pole

Figure 1a. NEMA 6-15 plug and receptacle.

Figure 1b. NEMA L6-20 plug and receptacle.

We recommend using a NEMA-style 6-15 plug
and outlet with the G0550 as shown in

Figure 1a

and an L6-20 plug and outlet for the G0551 as
shown in

Figure 1b. You may also “hard-wire”

the planer directly to your panel, provided you
place a disconnect near the machine. Check the
electrical codes in your area for specifics on
wiring requirements.

Plug-Type

Circuit Breaker

Amperage Draw

SECTION 3: CIRCUIT REQUIREMENTS

Advertising