2.8 BATTERY

INSTALLATION

2.8.1 RECOMMENDED BATTERY

Install a battery that meets the following
requirements:
• The battery must be a 12-volt, automotive type

storage battery.

• For prevailing ambient temperatures above 32° F

(0° C), use a battery rated 70 amp-hours and capa-
ble of delivering 400 cold-cranking amperes.

• For prevailing ambient temperatures below 32° F

(0° C), use a battery rated 95 amp-hours and capa-
ble of delivering 400 cold-cranking amperes.

NOTE:

If the battery is to be used to power other vehicle
accessories, as well as start the generator, you may
need a battery with a larger capacity.

2.8.2 BATTERY CABLES

Using battery cables that are too long or too small in
diameter may cause a drop in voltage, which causes
starting problems. For the best cold weather starting,
the voltage drop between battery terminals and the gen-
erator connection point should not exceed 0.12 volts
per 100 amperes of cranking current.
PRIMEPACT generators are rated at about 100 DC
amperes of cranking current.
Select battery cables based on (a) cable length and (b)
prevailing ambient temperatures. Generally, the longer
the cable and the colder the weather, the larger the
cable size must be, as shown in the chart.

2.8.3 BATTERY CABLE CONNECTIONS

1. Connect the battery cable from the battery post or

terminal indicated by a POSITIVE, POS or (+) to
the lug on the starter contactor (Figure 2.20).

NOTE:

Check to be sure the battery cable boot for the
starter cable has been installed.

2. Connect the battery cable from the battery post

indicated by a NEGATIVE, NEG or (-) to the
frame ground connection (Figure 2.20).

3. Connect cables so the connectors are clean

and tight.

Figure 2.20 – Connecting Battery Cables

2.8.4 BATTERY COMPARTMENT

Install the generator battery in its own, vented com-
partment. Place the battery compartment away from
any source of heat, sparks or flame.
Provide ventilation openings in the battery compart-
ment. The minimum size of openings should be 2
square inches at the top of the compartment. Mount
the battery on a strong, rigid supporting structure,
where leaks and spills of battery fluid will not cause
damage.

2.9 OPTIONAL

ACCESSORIES

A plug-in receptacle (Figure 2.21) is provided on the
generator set, above the muffler enclosure. Use this
receptacle to connect an optional remote-mounted
start/stop panel to the generator. Installation of such
a panel will permit you to start and stop the genera-
tor engine from any convenient location inside the
vehicle.

Figure 2.21 – Remote Panel Plug-in Receptacle

Section 2 – Installation

PRIMEPACT 50 Recreational Vehicle Generator

CABLE LENGTH

in Feet (meters)

CABLE SIZE

0 to 10 (0 to 3)

2*

11 to 15 (3.4 to 4.5)

0

16 to 20 (4.5 to 6)

000

*For warm weather, use No. 2 cable up to 20 feet.