Auxiliary controls, Auxiliary controls –8, Auxiliary controls on your zoneline – GE Zoneline TINSEA530JBRZ User Manual

Page 5: Auxiliary controls—dip switches, Cooling—smart fan, Heating—smart fan, Remote thermostat—class 2

Advertising
background image

Auxiliary Controls on your Zoneline.

ge.com

Auxiliary Controls—Dip Switches

The auxiliary dip switch controls are located
behind the room cabinet, through an opening
in the control panel.

Remove the room cabinet. See the To Remove the
Room Cabinet section.

The owner is responsible for checking switches
and ensuring they are in the desired position.

HIGH

COOL

1

2

3

4

5

6

1

2

3

4

5

6

7

8

UP

DOWN

UP

DOWN

ALLI

2

R (All Electric Heat)

(3900 Series models only)

C: FAN CN (Cooling–Smart Fan)

H: FAN CY (Heating–Smart Fan)

CLASS 2 (Remote Thermostat)

LOAD SHEDDING (CDC)

FREEZ Sen (Freeze Sentinel)

CONST FAN (Constant ON Fan)

No Function (Reserved for future use)

TL1 (H) (Temp. Limit 1–Heat)
TL2 (H) (Temp. Limit 2–Heat)
TL3 (H) (Temp. Limit 3–Heat)

TL1 (C) (Temp. Limit 1–Cool)
TL2 (C) (Temp. Limit 2–Cool)
TL3 (C) (Temp. Limit 3–Cool)

7

8

Heat Sentinel

HEAT BOOST
(3900 Series models only)

Safety Instructions

Operating Instructions

Care and Cleaning

Tr

oubleshooting T

ips

Consumer Support

All Electric Heat

This electric heat option functions only on the
3900 Series models. When this switch is enabled
(UP), heat pump operation is locked out, causing
the unit to provide only electric resistance heat.

Cooling—Smart Fan

When this switch is enabled (UP), it allows the
indoor fan to cycle on/off with the compressor.
When this switch is disabled (DOWN), it allows
the indoor fan to run continuously.

Heating—Smart Fan

When this switch is enabled (UP), it allows the
indoor fan to run continuously. When this
switch is disabled (DOWN), it allows the indoor
fan to cycle on/off with the heat pump or
heater operation.

ALLI

2

R (All Electric Heat)

C: FAN CN (Cooling–Smart Fan)

H: FAN CY (Heating–Smart Fan)

Dip Switches

Access Cover

Remote Thermostat—Class 2

When this switch is enabled (UP), it allows the
unit to operate with a Class 2 Remote Control
Wall Thermostat. The unit controls are disabled.

CLASS 2 (Remote Thermostat)

5

Advertising