GE

®

5.4 Cu. Ft. Large Capacity Modular Commercial Electric Dryer

Dimensions and Installation Information (in inches)

Specification Revised 5/09

For answers to your Monogram,

®

GE Profile

or

GE

®

appliance questions, visit our website at

ge.com or call GE Answer Center

®

service,

800.626.2000.

For complete information, see installation instructions packed with your dryer.
Important Note:

GE Kit Number WE14X70 needed when converting rear exhaust to bottom or side.

(On large capacity models.)

Ducting Materials:

For best performance, this dryer should be vented with 4" diameter all rigid metal

exhaust duct. If rigid metal duct cannot be used, then UL-listed flexible metal (semi-

rigid) ducting can be used (Kit WX08X10077). In special installations, it may be

necessary to connect the dryer to the house vent using a flexible metal (foil-type)

duct. A UL-listed flexible metal (foil-type) duct may be used ONLY in installations

where rigid metal or flexible metal (semi-rigid) ducting cannot be used AND where a

4” diameter can be maintained throughout the entire length of the transition duct.

Please see installation instruction packed with your dryer for complete instructions

when using flexible metal (foil type) ducting.

Exhaust Length Calculation

1. Determine the number of 90° turns needed for your installation. If you exhaust to

the side or bottom of dryer, add one turn.

2. The maximum length of 4' rigid (aluminum or galvanized) duct which can be

tolerated is shown in the table.

A turn of 45° or less may be ignored. Two 45° turns within the duct length should be

treated as a 90° elbow. A turn over 45° should be treated as a 90° elbow.

Dryers

must be exhausted to the outside.

Caution: For personal safety do not terminate exhaust into a chimney, under any

enclosed house floor (crawl space), or into an attic, since the accumulated lint could

create a fire hazard or moisture could cause damage. Never terminate the exhaust

into a common duct or plenum with a kitchen exhaust, since the combination of lint

and grease could create a fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts,

bird nesting, etc. The wall cap must also be located at least 12" above the ground or

any other obstruction with the opening pointed down.

Special Installation Requirements
Alcove or Closet Installation:

• If your dryer is approved for installation in an alcove or closet, it will be stated on a label on the
dryer back.
• The dryer MUST be exhausted to the outside.
• Minimum clearances between dryer cabinet and adjacent walls or other surfaces are:

0" either side
3" front and rear

• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52".
• Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in.

of open area equally distributed.
If this closet contains both a washer and a dryer, doors must contain a minimum of 120 sq. in. of
open area equally distributed.

• The closet should be vented to the outdoors to prevent gas pocketing in case of a gas leak in the

supply line.

• No other fuel-burning appliance shall be installed in the same closet with the dryer.
Bathroom or Bedroom Installation:
• The dryer MUST be exhausted to the outdoors.
• The installation must conform with the local codes, or in the absence of local codes, with the

Natioinal Electric Code and National Fuel Gas Code, ANSI Z223 for gas dryers.

Minimum Clearances other than Alcove or Closet Installation:
• Minimum clearances to combustible surfaces

0" both sides
3" rear

Dryer Exhausting Information – Use Metal Duct Only

Best performance

Domestic

dryer models

Maximum length of 4"

dia.

rigid metal duct

Number

of

90°

turns

Exhaust hood type

A

4"

opening

B

2-1/2"

opening

5.7 cu. ft., capacity

electric and

gas dryers

0

1

2

3

4

60 ft.

52 ft.

44 ft.

32 ft.

28 ft.

48 ft.

40 ft.

32 ft.

24 ft.

16 ft.

5.4 cu. ft., capacity

electric and

gas dryers

0

1

2

45 ft.

35 ft.

25 ft.

30 ft.

20 ft.

10 ft.

A

4

B

2-1/2

A

Advertising