Installation and Operating Instructions

GENERATOR SAFETY TRANSFER SWITCH MODELS 2026, 3028, 3016, 3026

Thank you for purchasing a GenTran

®

Manual Transfer Switch designed

to safely connect a portable generator to the load center in your home
or business (single phase only) for standby power applications.
Product features include:

Generator and Utility feeds mechanically interlocked to prevent dangerous utility
or generator back feeding – thereby avoiding property damage and serious injury
to electrical workers.

Pre wired for fast, easy connection to the load center

Each model can be expanded to up to 10 circuits using interchangeable type
circuit breakers – so as your needs change, just expand it!

Accommodates GFCI and Arc-Fault breakers to meet the latest NEC requirements.

Dual wattmeters help you monitor and balance the loads on your generator,
prolonging generator life (not included on model 3016)

Flexible generator connections – Use the Power Inlet on models 2026 and 3028
for a quick cord connection to your generator, or hardwire the generator
connection.

Surface or Flush Mounting (with flush mounting plate sold separately).


Warning: Gen/Tran transfer switches should be installed by a professional electrician familiar with electrical wiring and codes, and
experienced in working with generators. Gen/Tran accepts no responsibility for accidents, damages or personal injury caused by
incorrect installation. These transfer switches are intended for surface mounting INDOORS only. GenTran transfer switches are UL
listed to UL Standard 1008 and meet the criteria of National Electrical code Article 702.6 for Optional Standby Systems.

Caution: If using the generator and transfer switch for larger appliances, such as electric water heaters, clothes dryers, electric
ranges and small air conditioners, check the labels on the appliances to be sure they do NOT exceed the rating of the generator. No
appliance should have an amperage rating that exceeds the individual breaker rating in the transfer switch (20 or 30 amps).

Model:

2026

3028

3016

3026

# Circuits Provided

6 8 6 6

Max # Circuits

10 10 10 10

REQUIRED BREAKER FOR MAIN
LOAD CENTER

(not included in this kit)

60 amp 2-pole

60 amp 2-pole

60 amp 2-pole

60 amp 2-pole

Breakers Provided with Unit

2 – 15 amp 1-pole
2 – 20 amp 1-pole
1 – 20 amp 2-pole

2 – 15 amp 1-pole
2 – 20 amp 1-pole
1 – 20 amp 2-pole
1 – 30 amp 2-pole

2 – 15 amp 1-pole
2 – 20 amp 1-pole
1 – 20 amp 2-pole

2 – 15 amp 1-pole
2 – 20 amp 1-pole
1 – 20 amp 2-pole

Max GEN Watts

5000 7500 7500 7500

Max GEN Amps

20 Amps

30 Amps

30 Amps

30 Amps

Voltage

120/240 Volts

120/240 Volts

120/240 Volts

120/240 Volts

NEMA Type Enclosure

1 – Indoor Only

1 – Indoor Only

1 – Indoor Only

1 – Indoor Only

NEMA Configuration of Male Inlet

L14-20

L14-30

N A

N A

Phase

1 1 1 1

Minimum Gauge Cord Size

12/4 10/4 10/4 10/4

Tools Needed for Installation:

Power Drill

Wire Stripper and cutter

Screw drivers

Tape measure

Wall anchors and screws

Other supplies needed if hardwiring to a Power Inlet
Box include standard building wire (like Romex

®

), ½”

connector, and wire connectors

2-pole 60 amp breaker for main panel

Advertising