Gp94ensrsa, Outdoor tankless water heater – GE GP94ENSRSA User Manual

Page 3

Advertising
background image

For answers to your Monogram,

®

GE Profile

or

GE

®

appliance questions, visit our website at

ge.com or call GE Answer Center

®

service,

800.626.2000.

Specification Created 1/08

GP94ENSRSA

GE

®

Outdoor Tankless Water Heater

Dimensions and Installation Information (in inches)

Installation:
Planning for plumbing
(shown with optional pipe cover)

The center of the pipes can be placed anywhere within the shaded area.
The center of the pipes is recommended to be protruding only within 6" of the mounting wall.
Other specific installations may be different.
Be sure that the minimum elevation of the bottom of the unit is 18" to meet the 36"
recommended clearance for the exhaust.
Note: It is recommended to install the bottom of the unit at least 18" off the ground to minimize
blockage from debris and provide room for the optional Pipe Cover Accessory, AGTPCM.

18” min.

9

7

8

2

1

2

2

1

2

2

1

2

4

1

2

7”

12”

3

3

8

6

1

2

9”

36” min.

Unit

Ground

18” min.

9

7

8

2

1

2

2

1

2

2

1

2

4

1

2

7”

12”

3

3

8

6

1

2

9”

36” min.

Water and gas

through the wall *

Ground

Unit

Pipe cover not required. However,
consideration should be taken in the
design of the rough plumbing to allow
installation of unit and pipe cover.

* Suggested area for Water and Gas lines to come

through the wall to allow the optional pipe cover
to be installed if desired.

Optional Pipe Cover (AGTPCM)
shown shaded.

Maximum Level

Total Hardness

Up to 200 mg/L (12 grains)

Aluminum*

Up to 0.2 mg/L

Chlorides

Up to 250 mg/L

Copper*

Up to 1.0 mg/L)

Iron*

Up to 0.3 mg/L

Manganese*

Up to 0.05 mg/L

pH*

6.5 to 8.5

TDS (Total Dissolved Solids)*

Up to 500 mg/L

Zinc*

Up to 5 mg/L

Water Quality:
Care for your water heater should include evaluation of water quality.
If the water exceeds the target levels provided in the table, you should
treat or condition the water. If not treated, water quality may alter the
life or performance of the product.

* Source: Part 143 National Secondary Drinking Water

Note: If you are in a hard water area (12 grains of hardness or
greater) installation of a GE Water Softener is recommended

380306

Advertising