ADJUSTMENT

1.

REGULATED B + ADJUSTMENT

Connect high impedance voltmeter between

emitter and ground rotate the B

adjustment control

to obtain a reading of

12.0

2.

FOCUS

Adjust the focus control (VR704) for best overall
focus of the test pattern (marked with the symbol

Usually the center and corners of the

screen do not focus at the same setting and a

compromise must be made.

3. VERTICAL

The vertical size control (VR601) should be adjust
for the picture to fill the screen vertically.

4. HORIZONTAL SIZE

The horizontal size control (H-site coil) should be
adjusted for the picture to fill the screen horizontal-
ly.

5. HORIZONTAL POSITION

The horizontal position control (VH701) snould be
adjusted for the horizontal picture position.

6. SUB-BRIGHT (VR703)

Adjust subbright control (VR703) for

cut off

of the raster when external brightness is turned to
maximum

7. CENTERING ADJUSTMENT

It the raster is not centered horizontally and verti-

cally it may be centered by removing the cabinet

back and adjusting the centering tabs on the neck

of the tube, located at the rear of the deflection
yoke. Turn the whole device clockwise or
counterclockwise. To increase the amount of raster
shift move the two tabs which project from the
device farther apart, if raster is tilted on an angle,

it may be straightened by loosening the deflection

yoke clamp and rotating the deflection yoke.

BLOCK DIAGRAM