17

REMEDIES

Verify the fuses are not

blown, a circuit breaker has

not tripped (also check the

breaker for controls), and the

heaters are not overloaded.

The wiring, heater switches

and starter must be inspected

for possible damage prior to

starting.

Make sure the motor is wired

across the proper voltage.

The required voltage is indi-

cated on the motor label.

With the circuit de-energized,

check for continuity using an

ohmmeter.

Confirm the circuit is wired for

single-phase or three-phase

and the motor is grounded.

Check safety shut-off circuitry

to make sure the necessary

circuit by-passes are in place

to start the motor.

Check single-phase motor

controller and verify that it is

in working order. See detailed

label inside controller box.

Check the amp draw through

each leg leading to the motor
using an ammeter. The read-

ings should not exceed the

maximum amps (S.F.A.) indi-

cated on the motor label.

POSSIBLE CAUSES

Blown fuse, tripped circuit

breaker or overloaded

Line voltage connection dif-

ferent from motor voltage

Bad connection

Motor wired improperly

Shut-off controls disabling

circuit.

Single-phase motor controller

not operational

Motor exceeding rated amp

draw

PROBLEM

Motor does not run

Motor runs, then stops

T R O U B L E S H O O T I N G G U I D E