Grizzly H5374 User Manual

Model h5374 ½ hp electric motor, Instruction sheet, Electrical safety

Advertising
background image

MODEL H5374

½ HP ELECTRIC MOTOR

INSTRUCTION SHEET

Electrocution or fire could

result if this motor is not

grounded correctly or if

your wire connections do

not comply with local and

state codes. Ensure com-

pliance by checking with a

qualified electrician!

Electrical Safety

If you are unsure how to attach wires to terminals,
DO NOT continue. Contact a qualified electrician
for assistance. Connecting wires improperly may
cause them to come loose or contact other wires,
which can cause electrocution, fire, or a short.

Model H5374 Specifications

Power ......................................................... ½ HP
Cycle ............................................................60Hz
Voltage .................................................110/220V
Prewired ......................................................110V
Amps ............................................................6/3A
RPM ............................................................. 1725
Phase ........................................................ Single
Class ..................................................................B
Start Capacitor ........................200MFD 125VAC

Dimensions .............................. 1½"D x 2

3

8

"L

Run Capacitor ...........................30MFD 250VAC

Dimensions ..............................1

3

/

8

"D x 2

3

8

"L

COPYRIGHT © DECEMBER, 2007 BY GRIZZLY INDUSTRIAL, INC.

WARNING: NO PORTION OF THIS INSTRUCTION SHEET MAY BE REPRODUCED IN ANY SHAPE

OR FORM WITHOUT THE WRITTEN APPROVAL OF GRIZZLY INDUSTRIAL, INC.

#JB10233 PRINTED IN TAIWAN

Replaceable Parts

REF PART #

DESCRIPTION

REF PART #

DESCRIPTION

1

PH5374001

MOTOR FAN COVER

6

PC030C

R CAPACITOR 30M 250V 1-3/8 X 2-3/8

2

PH5374002

MOTOR FAN

7

PH5374007

JUNCTION BOX

3

PH5374003

S CAPACITOR COVER

8

PH5374008

CENTRIFUGAL SWITCH

4

PC200C

S CAPACITOR 200M 125V 1-1/2 X 2-3/8

9

PH5374009

CONTACT PLATE

5

PH5374005

R CAPACITOR COVER

Disconnect power when

replacing motor. Failure

to do this may result in

serious personal injury.