Slave to Slave Interconnect

A second slave fan/heater unit can be added to
operate in unison with the master fan/heater unit
and another slave fan/heater unit. This would cre-
ate a three fan unit. The interconnect between
the first slave fan/heater unit and the second slave
fan/heater unit remains the same regardless of
the type or presence of a control center. To wire
a second slave fan/heater unit to another slave
fan/heater unit do the following:

Figure 27: Wiring for a second slave fan/heater unit to another slave fan/heater unit.

ELECTRICAL POWER SUPPLY

NOTE: Do NOT use solid wire for inter-
connection.

1. Run four (4) 16ga MTW type wires

from the first slave fan/heater unit to
the second slave fan/heater unit.

2. Connect the wires as shown in figure

#27.

NOTE: A shielded 16 gauge cable is recom-
mended for use on the network connections. The
network connections for this configuration are
attached to terminals number 7 and 8 in slave #1
and terminals number 3 and 4 in slave #2.
Ground each end of the shielded cable to the
housing. A shielded 16 gauge 2 wire cable can
be purchased from GSI. Part #WR-16 / 2S