Notice, Shutdown procedure – Grizzly H8191 User Manual

Page 17

Advertising
background image

H8191 3600 PSI Diesel Pressure Washer

-15-

11. Allow the motor to run for at least two minutes

to achieve normal operating temperature,
then set the speed control lever to the desired
speed.

NOTICE

Never allow the motor to run for more than

five minutes without pulling the trigger

on the spray gun to release water. Failure

to follow this instruction can damage the

pump and void the warranty.

5. Switch the motor to the START position by

loosening the speed control lever locking
bolt, moving the mechanism downward, and
retightening the bolt next to the word "START"
(

Figure 5, Page 10).

6. Open the fuel valve by rotating the lever

clockwise until it is vertical (

Figure 14).

When pull-starting, pull the start rope

slowly until resistance is felt, then pull with

forceful, even pressure. Rapidly jerking the

start rope can cause it to forcefully recoil,

potentially causing hand or arm injury.

NOTICE

To reduce the risk of damaging engine

components, DO NOT stop the engine

abruptly when it is running under load.

NEVER attempt to stop the motor with the

compression release lever.

Shutdown Procedure

To shut down the pressure washer:

1. Release the spray gun trigger and return

the spray gun to the bracket on the washer
handle.

2. Allow the motor to run without pulling the

spray gun trigger for 4 minutes.

3. Switch the motor to the STOP position by

loosening the speed control lever locking
bolt, moving the mechanism upward, and
retightening the bolt next to the word "STOP"
(

Figure 5).

4. Close the fuel valve by rotating the lever

counterclockwise until it is horizontal.

5. Shut off the water at the spigot, or remove

the input line from the water if drawing from a
standing source. Purge the pressure from the
system by pulling the spray gun trigger.

12. Pull the trigger on the spray gun to release

pressurized water and begin spraying.

Note: If the motor does not start after several
pulls of the start rope or brief turns of the
start switch, repeat the starting instructions
from

Step 7. If you are still unable to start the

motor, refer to

Troubleshooting on Page

22.

Figure 14. Fuel valve in open position.

7. Squeeze the spray gun trigger until a steady

stream of water comes out, then release.

8. Unlock the compression release lever by

pulling the start rope until resistance is felt.

9. Push the compression release lever down

until it latches.

10. Pull the start rope handle with forceful, but

even pressure, or turn the electric start switch
to start the motor.

Fuel Valve

Advertising