Installation instructions, Installing the water line, Connect the tubing to the refrigerator – GE 197D5226P005 User Manual

Page 10: Turn the water on at the shutoff valve, Plug in the refrigerator, Start the icemaker, Cont.)

Advertising
background image

CONNECT THE TUBING TO THE
REFRIGERATOR

(CONT.)

Fasten the tubing into the clamp provided to
hold it in a vertical position. You may need to
pry open the clamp.

7

Installation Instructions

10

CONNECT THE TUBING TO THE
REFRIGERATOR

NOTES:

• Before making the connection to the refrigerator,

be sure the refrigerator power cord is not plugged
into the wall outlet.

• We recommend installing a water filter if your

water supply has sand or particles that could clog
the screen of the refrigerator’s water valve. Install
it in the water line near the refrigerator. If using
GE SmartConnect

Refrigerator Tubing kit,

you will need an additional tube (WX08X10002)
to connect the filter. Do not cut plastic tube to
install filter.

Remove the access cover.

Remove the plastic flexible cap from the water
valve (refrigerator connection).

Place the compression nut and ferrule (sleeve)
onto the end of the tubing as shown. On GE
SmartConnect

Refrigerator Tubing kit,

the nuts are already assembled to the tubing.

Insert the end of the tubing into the water valve
connection as far as possible. While holding the
tubing, tighten the fitting.

For plastic tubing from a GE SmartConnect

Refrigerator Tubing kit, insert the molded end
of the tubing into the shutoff valve and tighten
compression nut until it is hand tight, then
tighten one additional turn with a wrench.
Overtightening may cause leaks.

7

TURN THE WATER
ON AT THE
SHUTOFF VALVE

Tighten any connections
that leak.

8

Tubing Clamp

1/4

″ Compression

Nut

Ferrule
(sleeve)

SmartConnect

Tubing

Refrigerator
Connection

1/4

″ Copper

Tubing

PLUG IN THE REFRIGERATOR

Arrange the coil of tubing so that it does not vibrate
against the back of the refrigerator or against the wall.
Push the refrigerator back to the wall.

9

Move the feeler arm to the

ON

(down) position. The

icemaker will not begin to operate until it reaches
its operating temperature of 15°F (–9°C) or below.
It will then begin operation automatically.

START THE ICEMAKER

Feeler Arm in the
STOP (up) position

Feeler Arm in
the ON (down) position

10

NOTE:

In lower water pressure conditions, the

water valve may turn on up to 3 times to deliver
enough water to the icemaker.

Reattach the access cover.

INSTALLING THE WATER LINE

(CONT.)

1

Advertising