Table 2.2

E-Series

Feed Water Requirements

*

American Standard for Testing Materials

2.6

Transporting Pure Water (Permeate) to Point-of-Use

The pure water, or permeate, is in an aggressive state and should only be transport-
ed from the machine to the point-of-use in food grade flexible nylon, stainless steel
(SS) tubing, or polyvinyl chloride (PVC) material for the inlet, permeate, and concen-
trate piping sizes. Refer to Connections (Table 2.1) for inlet, permeate, and concen-
trate piping sizes.

WARNING:

MACHINE DAMAGE MAY OCCUR IF PERMEATE BACK PRESSURE
EXCEEDS 60 PSIG (4.1 BARG) DURING OPERATION.

3

Temperature

Inlet Pressure

Chlorine
(continuous feed)

Operating pH

Silt Density
Index (SDI)

Typical:

50° - 85°F (10° - 29°C)

Limits:

33° - 104°F (0.16° - 40°C)

Minimum:

30 psig (2.1 barg)

Maximum:

60 psig (4.1 barg)

0 parts per million (ppm)

5.5 - 8.5

Less than or equal to 5 to minimize
membrane element fouling and
extend cleaning intervals.
Refer to ASTM* standard D4189.