Installation, 5installation instructions, Take measurements – GE JVB65 User Manual

Page 5: Requirements for an approved installation, Specifications

Advertising
background image

5

INSTALLATION INSTRUCTIONS

Before Starting Installation Check the
Following Requirements

This downdraft blower system is designed to be
used to exhaust smoke and odors when cooking
with all GE electric and sealed burner gas
cooktops (not approved for standard burner gas
cooktops). It can be mounted in either an island
or peninsula location.

Requirements for an approved installation

• 26

minimum cabinet depth

• 26

minimum from the back of the downdraft

to the front of the countertop, with
• 23

1

2

minimum FLAT countertop surface

• Plan the placement of the electrical outlet box
carefully. It should NOT be installed on the back
wall of the cabinet because it may interfere with
the downdraft. It should be installed on a side
wall or adjacent cabinet. Make sure it is within
reach of the unit’s 2 ft. long power cord and
conforms to all local codes.
Install a standard wiring box with a 3-pronged
outlet.
• Plan the location of the gas supply pipe (for
gas cooktops) carefully to avoid interference
with the downdraft installation.

Specifications

This unit can be easily installed following these
basic steps:
• Cut out the countertop opening.
• Install the downdraft in the cabinet.
• Connect the ductwork and electrical.
• Install the cooktop.

VOLTS

AMPS

CFM

DUCT

120

4.0

500

3

1

4

X 10

Take Measurements

Refer to the cooktop installation instructions for
dimensions of cooktop, countertop cut-out, and
cabinet requirements.
The 30

models will fit in most 30

wide

cabinets and the 36

models will fit in most 36

wide cabinets.
To install a cooktop with this downdraft, the
cabinet depth must be 26

minimum.

A countertop with a raised lip may not allow
enough flat countertop for a proper installation.
Before starting installation review the following
pages carefully.
Cutout dimension and illustrations are given for
30

and 36

cooktops.

Flat counter

area

26

Minimum 26

Cabinet depth required

(continued next page)

Advertising
This manual is related to the following products: