Table 5 -Performa 960 FA Level I Programming Parameters

Parameter

Range of Values

Minimum

Increments

Default

Units of Measure

Notes

Name

Description

P1

Time of day

AM or PM

1:00 to 12:59

00:00 to 23:59

1

None

Hour: minute

Range depends on value selected

for P13. Enter the current time.

P2

Time of day of

regeneration

1:00 to 12:59

AM or PM

00:00 to 23:59

1

2:00 AM

Hour: minute

Range depends on value selected

for P13. Skip this parameter to

accept the default or enter a new

time.

P3

Factor A

3 to 250

30 to 2500

1

10

10

100

PPM

PPM x 10

Unit of measure depends on value

selected for P12. Enter potassium

permanganate demand.

P4

Regenerant

Dosage

0.5 to 99.5

01 to 25.5

0.5
0.1

6

2.5

Gallons x 10

Liters x 10

Unit of measure depends on value

selected for P12.

Select regenerant dosage from

Table 6 and enter that value.

P5

Capacity of Unit

0.1 to 140.0

0.01 to 14.00

0.1

0.01

1.0
0.1

PPM-gallons

PPM-liters

Unit of measure depends on value

selected for P12.

Enter the system capacity setting

from Table 7.

Table 6 - Regenerant Dosage Settings (gallons x 10) for Various Size Iron Filters

Temperature

Filter Size/Cubic Feet of Manganese Greensand

0.75 ft

3

1.00 ft

3

1.25 ft

3

1.50 ft

3

1.75 ft

3

2.00 ft

3

2.50 ft

3

3.00 ft

3

3.50 ft

3

50

°F

4.0

5.0

6.0

8.0

9.0

10.0

13.0

15.0

18.0

60

°F

3.0

4.0

5.0

6.0

7.0

9.0

9.0

11.0

13.0

70

°F

3.0

3.0

3.0

4.0

4.0

5.0

6.0

8.0

9.0

Table 7 - Capacity Settings for Various Size Iron Filters

Filter Size

0.75 ft

3

1.00 ft

3

1.25 ft

3

1.50 ft

3

1.75 ft

3

2.00 ft

3

2.50 ft

3

3.00 ft

3

3.50 ft

3

Capacity Setting

7.5

10

12.5

15

17.5

20

25

30

35