Draining tank, Pressure safety valve, Monthly – Grizzly G0471 User Manual

Page 19: Quarterly

Advertising
background image

Model G0471 3 HP Air Compressor

-

17

-

Monthly

After the first 50 working hours or 30 days,
perform the following maintenance:

1. Change the oil in the air compressor

pump as described in

Changing Oil on

Page 21.

Quarterly

After every 300 working hours or 3 months,
perform the following maintenance:

1. Change the oil in the air compressor

pump as described in

Changing Oil on

Page 21.

2. Check for air leaks and correct as

needed.

Figure 14. Pressure safety valve.

2. Clean any dirt or dust from the pres-

sure safety valve.

3. Pull the metal ring on top of the safety

valve to ensure the valve will release
air. The pressure safety valve must be
replaced if it cannot be pulled, or if it
leaks after releasing pressure.

Note: The safety valve is preset to
release air if the tank exceeds its maxi-
mum pressure. DO NOT try to adjust
the safety valve pressure setting!

Some water may accumulate in the tank
depending on usage and humidity. Drain
water from the tank daily to increase the
lifespan of the compressor and air tools.

To drain the tank:

1. Leave the tank pressurized and open

the drain valve, shown in

Figure 13, to

drain the water out of the tank.


Note: Draining the air from the tank will
be extremely loud. Wear ear protection
when draining the tank.

Draining Tank

The pressure safety valve prevents dam-
age to the tank by releasing pressure when
the tank reaches maximum capacity.

To check the pressure safety valve:

1. Locate the pressure safety valve shown

in

Figure 14.

Figure 13. Tank drain valve.

Pressure Safety

Valve

Releasing the safety valve will be
extremely loud. Protect your hearing
with ANSI approved ear protection.

Pressure

Safety Valve

Advertising