MODEL

PTS/U 40

40,000

40,000

25,000

PTS/U 50

50,000

50,000

30,000

PTS/U 75

75,000

75,000

50,000

PTS/U 100

100,000

100,000

65,000

MODEL SELECTIONS

GENERAL FEATURES

8 different Btu/hr sizes and more than 100
different configurations to custom design your
infrared heating system

Single Stage or Two Stage Input Controls

CSA design certified

Vented or indirect vented operation

Sidewall or through-the-roof venting

Natural and propane gas models

PUSH THROUGH SYSTEM

(Positive Pressure)

Products of combustion are pushed through the
combustion chamber

Tube Integrity Safety System (TISS)

No draft hoods, totally enclosed
combustion chamber

Blower motor totally enclosed in the burner box.
Ideal for applications where minimal noise (less
than 60dB) is desired

Heavy duty permanently lubricated, ball bearing
blower motor for maintenance-free operation

BURNER SYSTEM

Heavy-duty cast iron burner

10-year limited warranty on burner

Inside or outside air for combustion

Up to 40 ft. outside combustion air duct capability

Standard 4” combustion air collar

Reliable direct spark ignition system and 100%
gas shut-off safety control

Pre-purge and post-purge function

State-of-the-art step opening redundant
combination gas valve for quiet ignition and
added safety

Diaphragm air switch for proof of venting before
gas flow and ignition

Diagnostic monitoring light system

Burner inspection sight glass

Line voltage or 24V thermostat connection

RADIANT EMITTER TUBE SYSTEM

4” O.D. heavy-duty calorized aluminized steel or
alumi-therm steel combustion chamber (10 feet)
and heavy duty hot-rolled steel radiant emitter
tubes

Optional calorized aluminized steel (ALC)
radiant emitter tubes

3-year limited warranty on the emitter tubes

Suitable for horizontal or angle mounting up to 45°

Optional 90° elbows

Up to 40 feet sidewall vent capacity

REFLECTOR SYSTEM

Highly efficient aluminum reflectors with
reflectivity rating of 97.5%

Optional end, corner, side and U-bend reflectors

Optional decorative grille

Individual reflectors can be rotated up to 45° to
direct heat where needed

Easy-to-use mounting brackets and wire hangers

TOTAL EMITTER TUBE LENGTH*

10 FT**

20 FT

30 FT

40 FT

PTS/PTU SERIES FEATURES

GAS

TYPE

NATURAL

3.5” W.C.

5” W.C*

14” W.C.

PROPANE

10” W.C.

11” W.C.*

14” W.C.

BURNER

PRESSURE

VOLTAGE

AMPS

IGNITION

TYPE

MIN

MAX

120 VAC

60 HZ

1.8

DIRECT

SPARK

*Indicate model number based on Btu/hr input (e.g., 100,000 Btu/hr), total emitter length, (e.g., 40 feet) and gas type
(e.g., natural gas single stage input). The unit selection for a straight tube would be PTS100-40-N5 and for a U-tube
would be PTU100-40-N5. **Available only on PTS models.

ALC Option: All calorized aluminized steel (ALC) radiant emitter tubes
for ALC option the model number would be PTS100-40-ALC-N5. Note: for Carwashes, Dairy Barns, Greenhouses,
Swimming Pools, Waste Water Treatment Plants, and other high humidity / corrosive environments, the ALC option with
all calorized aluminized tubes is recommended.

SUPPLY PRESSURE

SINGLE

STAGE

BTU/HR

INPUT

FLUE

CONNECTION

OUTSIDE COMBUSTION

AIR CONNECTION

4” Round

4” Round

Btu/hr

High Input

Btu/hr

Low Input

TWO STAGE

X

X

X

X

X

X

X

X

MODEL

PTS/U 125

125,000

125,000

80,000

PTS/U 150

150,000

150,000

100,000

PTS/U 175

175,000

175,000

110,000

PTS/U 200

200,000

200,000

125,000

TOTAL EMITTER TUBE LENGTH*

30 FT

40 FT

50 FT

60 FT

70 FT

SINGLE

STAGE

BTU/HR

INPUT

Btu/hr

High Input

Btu/hr

Low Input

TWO STAGE

X

X

X

X

X

X

X

X

X

X

X

X

CONTROL SUFFIX

N5 / L5

N7 / L7

TYPE OF GAS

Natural / Propane

Natural / Propane

CONTROL OPTION DESCRIPTION

Single Stage Gas Valve - Single Stage Input

Two Stage Gas Valve - Two Stage Input - High/Low Fire

®

Energy efficient PTS150-40 installed in a manufactur-