Flow chart to fault finding

Unit does not

operate

Check

Power Supply

Connection OK?

No

Yes

Connect Unit

Is there any

LED

Indication?

No

Short circuit

connection

Potentiometer?

Check

potentiometer

connection

Check LED

Yes

No

Disassemble

Cooker top

assembly

Replace LED

Defective

OK

Check fuse

T10A

Check rectifier

DefectIve

Replace

Power Board

OK

OK

Check electric

Potential DC

Volts

Defective

Check IGBT

Transistor’s

Replace

Power board

Error

Check fuse

T1A

OK

Check power

Print (board)

visually

Check wiring

Error

Correct wiring,

connections

Wired

incorrectly

Check power

cord/plug &

socket

OK

Replace

Fuse

Is there any

Error codes ?

Error code in

IR Mode ?

Utilize error

code and go

ahead

according to list

Yes

No

Yes

Cooker does

not operate

Replace

Power Board

Cooker operates

Unit works.

Continuous test for

about 10 minutes is

necessary

Yes

Contact

Electrician

Defective

OK

Check if fuse is

installed correctly