220v connection, Optional 110v connection, Motor direction 220v – Grizzly G0709 User Manual

Page 80: Motor direction 110v

Advertising
background image

Model G0709 (Mfg. Since 5/11)

-78-

READ ELECTRICAL SAFETY

ON PAGE 74!

Main Motor

Spindle Motor 110v & 220v connection

If the lathe chuck rotates in the
opposite direction of what the
spindle ON/OFF lever indicates,
disconnect the lathe from power. At
the motor junction box, swap the
positions of the wires marked U

1

and

U

2

. This will match the motor and

spindle rotation to what is indicated
at the spindle ON/OFF lever.

MOTOR DIRECTION

220V

Ground

Run Capacitor

20M 400V

Start Capacitor

150M 250V

220V

Connection

Ground

Run Capacitor

20M 400V

Start Capacitor

150M 250V

Optional

110V

Connection

If the lathe chuck rotates in the
opposite direction of what the
spindle ON/OFF lever indicates,
disconnect the lathe from power. At
the motor junction box, swap the
positions of the wires marked Z

1

and

Z

2

. This will match the motor and

spindle rotation to what is indicated
at the spindle ON/OFF lever.

MOTOR DIRECTION

110V

d

d

U2

Z1

Z2

Z2

U2

Z1

U1