Door ventilation opening, Miscellaneous requirements, Installation instructions – GE WSM2780 Gas User Manual

Page 8: Warning

Advertising
background image

Installation Instructions

DOOR VENTILATION OPENING

A minimum of 120 square inches of opening, equally
divided at top and bottom, is required. Air openings are
required to be unobstructed when a door is installed.
A louvered door with equivalent air openings for the
full length of the door is acceptable.

When louvers or registers are placed in door openings,
the free air openings of the louvers or registers must
equal 120 square inches.

60 Sq. In.

60 Sq. In.

WARNING –

For your safety, the information in this manual must
be followed to minimize the risk of fire or explosion or to
prevent property damage, personal injury or loss of life.

• Do not store or use gasoline or other flammable vapors

and liquids in the vicinity of this or any other appliance.

• WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

• Do not touch any electrical switch; do not use any

phone in your building.

• Clear the room, building or area of all occupants.

• Immediately call your gas supplier from a neighbor’s

phone. Follow the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire

department.

Installation and service must be performed by a qualified
installer, a service agency or the gas supplier.

MISCELLANEOUS REQUIREMENTS

LOCATION

• The appliance must be installed on firm flooring to

minimize vibration during spin cycles. Concrete flooring
is best; but wood base is sufficient, providing the floor
support meets FHA standards.

• The appliance should not be installed on rugs or

exposed to the weather.

8

Advertising