Grizzly G0470 User Manual

Page 20

Advertising
background image

model G0464/G0465/G0467/G0468/G0470 (mfg. since 9/04)

-

18

-

symptom

possible cause

possible solution

Loud repetitious noise
coming from air com-
pressor.

1. Pulley setscrews or keys

are missing or loose.

2. motor fan is hitting the

cover.

1. Inspect keys and set-

screws. Replace or
tighten if necessary.

2. Adjust fan cover mounting

position, tighten fan, or
shim fan cover.

Low pressure at the
tool.

1. Pressure regulator.

2. Air leaks in hoses.

3. Pressure gauge bad.

4. Pressure switch turns the

motor

OFF too soon.

1. Adjust pressure regulator,

if no improvement, inspect
regulator for leaks or
replace.

2. Check air hoses and all

connections for leaks (see
page 20).

3. Replace the pressure

gauge.

4. Adjust the pressure switch

(see

page 21).

Low pressure at the
tanks, or tank pressure
drops after compressor
is turned

OFF.

1. Air leaks in tanks or deliv-

ery pipes.

2. Drain valve open.
3. Air filter clogged.
4. Leaking check valve.

5. Pressure relief valve

releasing below 110 PSI.

6. Gaskets leaking.

7. Worn rings.

8. Pressure switch turns the

motor

OFF too soon.

1. Check air tanks, pipes and

all connections for leaks
(see

page 20).

2. Close drain valve.
3. Inspect and clean air filter.
4. Repair the check valve

(see

page 19).

5. Replace pressure relief

valve.

6. Check gaskets on cylinder

head assembly, repair or
replace as needed.

7. Inspect and replace pump

piston rings.

8. Adjust the pressure switch

(see

page 21).

Compressor knocking.

1. Improper oil level.

2. Air filter clogged.
3. Piston assembly loose.

1. Check oil level and add oil

(see

page 9).

2. Inspect and clean air filter.
3. Inspect and repair piston

and connecting rod.

Pressure relief valve
stays open and motor
won’t stop running.

1. Pressure switch adjusted

too high.

2. Faulty pressure switch,

unit is trying to overpres-
sure the tank.

3. Faulty pressure relief

valve.

1. Adjust the pressure switch

(see

page 21)

2. Turn compressor

OFF,

unplug from power sup-
ply, and empty tank.
DO NOT USE until switch
is replaced.

3. Relief valve is reliev-

ing pressure too early.
Replace pressure relief
valve.

Advertising