Slant/Fin Galaxy Metal Gear User Manual

Page 3

Advertising
background image

Delete gas valve, thermocouple, pilot and pilot orifice from standard
(standing pilot) parts list. Add:

3

SLANT/FIN

HONEYWELL IID CONTROL SYSTEM

PART NO.

APPLICATION

Electric ignition pilot:

Honeywell Q345A - natural gas

411612

All natural gas boiler sizes

or

* Honeywell Q3451B - natural gas

412075

All natural gas boiler sizes

Honeywell Q345A - propane gas

411857

All propane gas boiler sizes

or

* Honeywell Q3451B - propane gas

412067

All propane gas boiler sizes

Pilot orifice

Natural gas only

410542

All natural gas boiler sizes

Propane gas only

410524

All propane gas boiler sizes

Gas valve - natural gas

Honeywell No. VR8204A, 1/2" x 3/4"

411864

GXH-105 thru GXH-190

Honeywell No. VR8304M, 1/2" x 3/4"

411927

GXH-210 thru GXH-300(H) and
GX-225, GX-250

Gas valve - L.P. propane gas

Honeywell No. VR8304M, 1/2" x 3/4"

411928

All propane gas boiler sizes

Pilot lighter - natural gas

Honeywell S8600F-1000

411873

All natural gas boiler sizes

Pilot lighter - L.P. propane gas

Honeywell S8600M-1013

411872

All propane gas boiler sizes

or S8670E-1007

411947

All propane gas boiler sizes

Ignition wire

411874

All boiler sizes

HONEYWELL IID CONTROLS
GALAXY - GX and GXH SERIES

Intermittent Ignition (IID)
Parts List

6

7C

7

7B

* Includes ignition wire

Advertising