background image

308–529

5

INSTALLATION

Figure 1

SPRAY

GUN

SPRAY

HOSE

QUICK

COUPLER

QUICK

COUPLER

HIGH

PRESSURE HOSE

CONNECTION

INLET WATER

CONNECTION 3/4”

GARDEN HOSE

Check for Shipping Damage

Check the unit for any damage that may have occurred

in shipping.

Notify the carrier immediately if there is

any damage.

Set Up

If you are using a downstream chemical injector, install

it between the pump unloader and the high pressure

hose, using the quick couplers provided.

Connect the high pressure hose between the pump

outlet and the gun inlet. Both of these connections are

made with quick couplers.

CAUTION

Up to 100 ft (30 m) of high pressure hose may

be used. Longer hoses may af

fect sprayer

performance, and chemical injector performance,

if used.

Install the appropriate spray tip on the wand.

See

Installing and Changing Spray Tips. If you are using a

sandblaster kit, see its separate manual for installation

instructions.

Connect to Water Supply

CAUTION

Before attaching to the water supply, check your

local plumbing code regarding cross– connection

to the water supply . A backflow preventer , P/N

801–133, is available to prevent backflow of

contaminated water into the fresh water supply .

Install it upstream from the pump.

If inlet water pressure is over 60 psi (4.1 bar) a

regulating water valve, P/N 800–258, must be

installed at the garden hose connection.

Do not exceed 160 _

F (70 _

C) inlet water

temperature.

Connect a hose with at least a 3/4 inch (19 mm) ID from

the water supply to the unit’s 3/4 inch garden hose inlet.

The supply hose should not be more than 50 ft (15 m)

long.

NOTE: The water source at the unit must have a

minimum flow rate equal to that of the unit

(see Technical Data, inside back cover).