Asic, Peration – Motorola CT-39A User Manual

Page 24

Advertising
background image

22

FT-8800R Operating Manual

F

REQUENCY

N

AVIGATION

1) Tuning Dial

Rotating the DIAL knob allows tuning in the pre-programmed steps established for the current
operating band. Clockwise rotation of the DIAL knob causes the FT-8800R to be tuned
toward a higher frequency, while counter-clockwise rotation will lower the operating frequency.

On the “Main” band frequency, press the DIAL knob momentarily, then rotate the DIAL
knob, to change the “Main” band frequency steps to 1 MHz per step. This feature is ex-
tremely useful for making rapid frequency excursions over the wide tuning range of the FT-
8800R.

2) Direct Keypad Frequency Entry (MH-48

A6J

Microphone)

The keypad of the MH-48

A6J

DTMF Microphone may be used for direct entry of the “Main”

band operating frequency.

To enter a frequency from the MH-48

A6J

keypad, just press the numbered digits in the

proper sequence. There is no “decimal point” key on the MH-48

A6J

keypad.

Examples: To enter 146.480 MHz, press [1]

[4]

[6]

[4]

[8]

[0]

To enter 433.000 MHz, press [4]

[3]

[3]

[0]

[0]

[0]

3) Scanning

From the VFO mode, press and hold the [SCN] key for one second, then rotate the DIAL
knob to select the bandwith for the VFO scanner. Now, press the [SCN] key momentarily to
initiate scanning toward a higher frequency. The FT-8800R will stop when it receives a
signal strong enough to break through the squelch threshold. The FT-8800R will then hold
on that frequency according to the setting of the “resume” mode (Menu #34 (SCAN); see
page 66). See page 39 for details regarding the VFO Scan operation.

If you wish to reverse the direction of the scan (i.e. toward a lower frequency, instead of a
higher frequency), just rotate the DIAL knob one click in the counter-clockwise direction
while the FT-8800R is scanning. The scanning direction will be reversed. To revert to
scanning toward a higher frequency once more, rotate the DIAL knob one click clockwise.

Press the [SCN] key again to cancel scanning.

B

ASIC

O

PERATION

Advertising