MAC 500/E User Manual

U t i l i t i e s

C a l i b r a t i o n ( C A L )

The calibration menu allows you to adjust the effects to achieve total uniformity between fixtures: it is not a substitute
for mechanical adjustment. Select dimmer/shutter (

d

O F

), color wheels (

C 1 O F

,

C 2 O F

), rotating-gobo wheel

(

R G O F

), fixed-gobo wheel (

F G O F

), or focus (

F O O F

) and adjust the effect’s offset with the arrow keys. Offsets are

adjustable from 1 to 255 for all effects except the fixed-gobo wheel, which is adjustable from 127 to 129. Press

[

ENTER

]

to save the calibration.

R e s e t d e f a u l t o f f s e t s (

S P E C / d F O F

)

Reset all calibrations to their factory defaults. Select

d F O F

and press [ENTER] when

S U R E

is displayed.

R e s e t d e f a u l t p e r s o n a l i t y s e t t i n g s (

S P E C

/

d F S E

/

F A C T

)

Return all personality settings (not calibrations) to their factory defaults. Select

F A C T

and press [ENTER] when

L O A D

is displayed.

C u s t o m c o n f i g u r a t i o n s (

S P E C

/

d F S E

/

C U S 1

,

C U S 2

,

C U S 3

)

Save and load 3 sets of custom configurations. To save a custom configuration, adjust the settings as desired, go to

C U S 1

,

C U S 2

, or

C U S 3

and press [ENTER] when

S A V E

is displayed. To load a custom setting, select it and

press [ENTER] when

L O A D

is displayed.

U p l o a d m o d e (

U P L d

)

Upload mode prepares the MAC 500/E to receive control software. It is normally engaged automatically when using
the MPBB1 or MP-2 uploaders

 In certain circumstances, however, you may have to set upload mode manually as

described under “Updating software” on page 23.