cord Sets and Receptacles

Use only high quality, well-insulated, grounded extension

cords with the generator’s 120 Volt duplex receptacle.

Inspect extension cords before each use.
Check the ratings of all extension cords before you use

them. Extension cord sets used should be rated for 125 Volt

AC loads at 20 Amps or greater for most electrical devices.

Some devices, however, may not require this type of

extension cord. Check the operator’s manuals of those

devices for the manufacturer’s recommendations.
Keep extension cords as short as possible to minimize

voltage drop.

wARNING

Overloaded electrical cords can overheat, arc,

and burn resulting in death, bodily injury, and/or

property damage.

• ONLY use cords rated for your loads.
• Follow all safeties on electrical cords.

120/240 volt Ac, 0 Amp, Locking Receptacle
Use a NEMA L14-30 plug with this receptacle. Connect a

4-wire cord set rated for 250 Volt AC loads at 30 Amps (or

greater). You can use the same 4-wire cord if you plan to

run a 120 Volt load.

This receptacle powers 120/240 Volt AC, 60 Hz, single phase

loads requiring up to 6,500 watts of power (6.5 kW) at 27.0

Amps for 240 Volts or two independent 120 Volt loads at

27.0 Amps each. The outlet is protected by a 2 pole rocker

switch circuit breaker and/or a 2 pole GFCI circuit breaker.

NOTIcE

Receptacles may be marked with rating value greater than

generator output capacity.

• NEVER attempt to power a device requiring more amperage

than generator or receptacle can supply.

• DO NOT overload the generator. See

Don’t Overload Generator.

120 volt Ac, 0 Amp Locking Receptacle
Use a NEMA L5–30 plug with this receptacle. Connect a

3–wire cord set rated for 125 Volt AC loads at 30 Amps to

the plug.

Use this receptacle to operate 120 Volt AC, 60 Hz, single

phase loads requiring up to 3,600 watts (3.6 kW) of power

at 30 Amps. The outlet is protected by a rocker switch circuit

breaker and/or a 2 pole GFCI circuit breaker.

120 volt Ac, 20 Amp Locking Receptacle
Use a NEMA L5–20 plug with this receptacle. Connect a

3–wire cord set rated for 125 Volt AC loads at 20 Amps to

the plug.

Use this receptacle to operate 120 Volt AC, 60 Hz, single

phase loads requiring up to 2,400 watts (2.4 kW) of power

at 20 Amps. The outlet is protected by a rocker switch circuit

breaker and/or a 2 pole GFCI circuit breaker.

120 volt Ac, 20 Amp, Duplex Receptacles
The duplex receptacles are protected against overload by

rocker switch circuit breakers and/or a 2 pole GFCI circuit

breaker.

3-Wire Cord Set

Neutral

120V

Hot

Ground (Green)

NEMA L-0

3-Wire Cord Set

Neutral

120V

Hot

Ground (Green)

NEMA L-20

4-Wire Cord Set

240V

120V

120V

W (Neutral)

Y (Hot)

X (Hot)

Ground (Green)

NEMA L14-0