O-rings damages or soiled

Clean or replace O-rings,

tighten screws fully

A. Air escapes between lid and housing:

Trouble shooting

Faults and possible causes

Remedy

B. Fasteners are not driven all the way in:

Working pressure too low.

Cross section of air hose too small.

Tool without lubrication

ncrease air pressure in 0.5 bar increments,

until fasteners are properly driven.

Min. 6 mm inner diameter required.

Clean parts and lubricate.

C. Fasteners are driven too far into the material

Working pressure too high.

Reduce working pressure in

steps of 0.5 bar.

D. Fasteners project or are bend:

Tool not held down firmly enough.

Hold down tool more firmly or increase

working pressure, if necessary.