MITSUBISHI ELECTRIC EXTRON 4XIXIXIXIXI User Manual

Page 2

Advertising
background image

Extron • System 4

xi

xi

xi

xi

xi

Switcher Series • User’s Manual • P/N 68-401-02 Rev. C

Mitsubishi Installation

Configuration and Connections

Page 2

(Note: Information depends on
System 4

NE

setup.)

(See note.)

(See note.)

(See note.)

(See note.)

[System 4

NE

model and software

version displayed here]

Connecting System 4

xi

xi

xi

xi

xi

to Mitsubishi LVP-X100

If the System 4

xi

is already configured for a Mitsubishi LVP-X100 projector, go

to step 4. If it is not set up correctly, it will be necessary to change switch
settings on the System 4

xi

’s Main Controller Board. Begin at Step 1 to verify the

correct configuration.

1. Use the Front Panel to display the Information Menu to verify that the System 4

xi

is already set up for the Mitsubishi LVP-X100. Apply power to the System 4

xi

and do the following:

a. Press

to display the M

ENU

S

ELECT

on the LCD screen.

b. Press

or

to step to Menu 8.

c. Press

to select this menu.

d. Press

or

to display the configuration. The example to the left is general,

yours will show the System 4

xi

model name, the software version and the

following information:
PRJ = MITS
PRJ BAUD = 9600
UNIT No. = 000
HST BAUD = 9600 (value depends upon setup Menu 3)

2. Go to the procedure on page 2-3 of the

System 4

xi

User’s Manual to remove the

System 4

xi

cover. Then go to page 2-4 and refer to the configuration below to

set up the Main Controller board. Continue with Step 3 (below) when the
configuration is correct.

Config

Projector

SW1: 1-2-3-4 SW2

SW3

SW4

SW5

SW6

Prj Cable

Comm

as

Adapter

Mits. LVP-X100

off-on-off-on

0

0

6

F

0

J15

26-475-01

3. Double-check your work and be sure the System 4

xi

cover is on securely.

4. Install the System 4

xi

in its place of operation (i.e. rack), but not powered on.

__________ Changes in some switch configurations are not detected until the power is

removed at the AC cord, and then restored.

Refer to the following connection diagram and continue.

5. The Mitsubishi LVP-X100 Comm Adapter (26-475-01) has a 9-pin male

connector that accommodates the Comm Extension cable. The other end of the
Comm Adapter plugs into the projector’s RS-232C port.

}

SW1

ON

SW2

SW4

SW3

SW5

J15

3

4

1

2