Description

The Murphy LM2000 model maintains the crankcase oil level of an engine,
pump or compressor. Adjusted to the correct running-oil-level, the LM2000 will
replenish oil as it is used. An integral, low-level switch will alarm and/or shut-
down the equipment if supply oil is lost and the equipment continues to use oil.

Specifications

Crankcase Balance Vent Connection: 1/2 NPTF (top).
Inlet Connection: 1/2 NPTF with removable screen (side).
Outlet Connection: LM2000 3/4 NPTF (bottom).

LM2000S 2 x 3/8 NPTF (side)

1 x 3/4 NPTF (bottom)

Thumb-Valve

TM

Material: Viton.

Snap-switch: SPDT rating 10 A, 125 VAC; 0.5 A, 125 VDC; 10 A, 30 VDC.
Wire leads: 18 AWG x 24 in.(609 mm) length.
Conduit Connection: 1/2 inch conduit (female, top).
Case: Die cast aluminum
Lens: Clear “Frog Eye” non-staining, high impact, high temperature nylon; UV

and heat stabilized.

Dial: High visibility white background with green and white “index” lines

for normal level indication.

Maximum Inlet Pressure: 9.50 psi/25 ft. oil (head pressure).
Maximum Case Pressure: 15 psi (103 kPa).
Maximum Differential: 2 in. (51 mm) between running and stopped.
Maximum Ambient Temperature: 250°F (121°C).
Float: Brass
Flow Rates: SAE 40 motor oil @ 32°F (0°C) with 2 ft. head pressure: 0.5

GPH (1.9 LPH).

NOTE: Friction losses due to piping not considered.

Optional Vent Fittings Kit: 15000954

The 15000943 kit is sold separately. It includes the following items:

Quantity

Description

1

Tubing vent (15050202).

1

1/4 x 1/4 NPT Connector (85030447).

Optional Hose Kit: 15000355

Quantity

Description

1

1/2 in. (13 mm) I.D. x 3 ft. (914 mm) long hose (89020202)

1

1 in. (25 mm) I.D. x 3 ft. (914 mm) long hose (89020203)

2 1/2

in.

(13 mm) worm gear clamp (00003502)

2 1

in.

(25 mm) worm gear clamp (00003503)

2

1/2 NPT x 1/2 in. (13 mm) barbed fitting (89080801)

2

3/4 NPT x 1 in. (25 mm) barbed fitting (89081001)

Thumb-Valve™ Operation

As the equipment uses oil, the float falls, providing immediate level compen-
sation. At FULL position, the float holds the valve closed. If the clean oil
supply is depleted and oil level continues to fall, the low level switch will
operate an alarm or equipment shutdown.

Service Parts

(

Specify part number)

Description

Part Number

Vent Fittings Kit

15000954

Hose Kit

15000355

1/2NPT x 1/2 in. Hose Barbed Fitting

89080801

3/4NPT x 1/2 in. Hose Barbed Fitting

89081001

3/8NPTF x 1/2 in. Hose Barbed Fitting

89080601

Pipe Bracket Kit

15000238

Universal Flange Kit

15010224

LM2000/LM2000S Lube Level Maintainer
Installation Instructions

LM-00011N

Revised 10-03

Section 15

(00-02-0423)

WARNING

BEFORE BEGINNING INSTALLATION OF THIS MURPHY PRODUCT

Disconnect all electrical power to the machine.

Make sure the machine cannot operate during installation.

Follow all safety warnings of the machine manufacturer.

Read and follow all installation instructions.

Please read the following information before installing. A visual inspection of this product for damage during shipping is
recommended before mounting. CRANKCASE MUST BE DRAINED BEFORE INSTALLATION.

GENERAL INFORMATION

COM.

(white)

N.O. (black)

Low Level Switch

LM2000
Case

Float

Action

Oil Inlet

Thumb-Valve™

FULL

LOW

N.C. (red)

Thumb-Valve

TM

and

Snap-switch
Schematic