Planning ductwork installation prepare the hood, Fig. 1 – Maytag UXT4036AA User Manual

Page 2

Advertising
background image

2

PLANNING DUCTWORK INSTALLATION

PREPARE THE HOOD

In more complex ducting situations, a 3-1/4" x 10" rectangular

ducting range hood (UXT3030AA and UXT3036AA hoods) can be

converted to a round duct by means of a transition.

(This section for UXT2030AA, UXT2036AA, UXT3030AA, and

UXT3036AA hoods only. UXT4030AA and UXT4036AA hoods
skip this section and go on to "Prepare the Hood".)

Begin planning ductwork by deciding where duct will run between

the range hood and the outside. For best performance, use the

shortest possible duct run and a minimum numaber of elbows.

There are several choices shown - FIGS. A - F below.

FIG. A

Ducting directly through the wall (for range hoods mounted on an

exterior wall). Shown are two ways to duct through an outside wall.

If a wall cap is used directly off the back of the hood, special care

must be taken to make sure that the damper in the damper/duct

connector on the hood damper in the wall cap do not interfere with

each other when the hood is operating. This could result in either

inadequate air delivery or backdrafts. If this condition does exist,

remove the hood damper flap. Sometimes when using a wall cap it

is easier to duct vertically and then use an elbow as shown FIG. B.

FIG. 1

1. Unpack hood and check contents. You should receive:

1 - Aluminum Filter (UXT3030AA, UXT3036AA, UXT2030AA

and UXT2036AA hoods only)

1 - 3¼" x 10" Damper/Duct Connector (mounted inside of

hood for shipping only) ((UXT3030AA and UXT3036AA

hoods only)

1 - Ductfree Filter (UXT4030AA and UXT4036AA hoods only)

2. Remove wiring box cover. Under cover find:

1 - Plastic Bag containing loose mounting hardware

ALUMINUM FILTER

(UXT3030AA, UXT3036AA,

UXT2030AA, UXT2036AA)

WIRING

BOX

COVER

KEYHOLE SLOTS

DUCTFREE FILTER

(UXT4030AA &

UXT4036AA HOODS

ONLY)

DAMPER/DUCT CONNECTOR

(UXT3030AA & UXT3036AA HOODS ONLY)

FIG. C.

Straight up through the roof us-

ing 7" round duct (for single story instal-

lations - UXT2030AA and UTX2036AA

only)

FIG. D.

Ducting straight up through the

roof using 3¼" x 10" rectangular duct. (For

single story installations UXT3030AA and

UXT3036AA hoods only.)

FIG. E.

Ducting between the ceiling joists

(for multi-story installations) or through the

soffit space above the cabinets (where the

soffit connects to an outside wall).

FIG. F.

Straight up through the roof

using 6" round duct (for single-story

installations).

Advertising
This manual is related to the following products: