Moffat Blue Seal E40AC User Manual

Page 2

Advertising
background image

4517 BS ACSeries specs V3 24/6/05 10:52 AM Page 18

Australia
Moffat Pty Limited

Victoria/Tasmania
740 Springvale Road
Mulgrave, Victoria 3170
Telephone 03-9518 3888
Facsimile 03-9518 3833
[email protected]

New South Wales
Telephone 02-8833 4111
[email protected]

South Australia
Telephone 03-9518 3888
[email protected]

Queensland
Telephone 07-3630 8600
[email protected]

Western Australia
Telephone 08-9562 0263
[email protected]

New Zealand
Moffat Limited

Christchurch
Telephone 03-389 1007
[email protected]

Auckland
Telephone 09-574 3150
[email protected]

Australia

www.moffat.com.au

New Zealand

www.moffat.co.nz

Printed in China
© Copyright Moffat Ltd
Moffat/4517-E40/BH/3.5M/6.05

Dimensions

Width

1290mm

Depth

895mm

Height

1950mm

Weight

395kg

Packed Dimensions

Width

1420mm

Depth

1220mm

Height

2250mm

Weight

505kg

Shelves

1/1 GN

40

2/1 GN

20

Shelf Spacings

67mm

Installation requirements

(for precise installation
instructions, please refer to the
unit’s installation manual).

Power connection requirements

Multi pole circuit breaker and all
pole disconnection isolator switch
installed near the appliance.

Supply line voltage;
400-415V ~ 50Hz, 3P+N+E

Special voltage options available
on request.

Power Connection

Total (kW)

61.8

Convection power (kW)

60

Rated Current (A) (400V)

90

IPX5 spray-proof and hose proof.

Installation clearances

- rear

25mm

- right

500mm*

- left

50mm

*Clearance required on fixed
installations for service
accessibility.

If heat sources are located near
the RH side of the AC combi,
ensure that a minimum distance
of 400mm is maintained.

Install in accordance with local
body regulations only on horizontal
surfaces and not against
combustible walls.

Water connection requirements

- Cold

water

- Flow pressure (2 to 6 bar)
- soft water connection*
- shut-off valve with return flow

inhibitor and dirt filter

- water supply R3/4
- R50 waste water connection

(*Water softener may be required.
Please refer to installation manual
for water treatment values.)

In line with policy to continually develop
and improve its products, Moffat Limited
reserves the right to change
specifications and design without notice.

T E C H N I C A L S P E C I F I C A T I O N S H E E T F O R

BLUE SEAL ELECTRIC COMBI STEAMER
AC SERIES E40AC DD 40 x 1/1GN or 20 x 2/1

A = WATER CONNECTION R

3

/

4

(SOFTENED WATER) refer to installation
manual for water treatment values.

B = WATER CONNECTION R

3

/

4

C = DRAIN CONNECTION Ø50
D = ELECTRICAL CONNECTION ENTRY
E = HIGH/LOW PRESSURE RELIEF VENT
F = OVEN VENT Ø80

Optional Extras

SC

Core temperature probe

KST40 Extra roll-in trolley to suit 40AC DD

KPT40 Plate banqueting trolley to suit 40AC DD

CPT40 Thermal cover for plate banqueting system to suit 40AC DD