En – 19, Adjustment from personal computer, English – MITSUBISHI ELECTRIC X50 User Manual

Page 19

Advertising
background image

EN – 19

ENGLISH

Adjustment from personal computer

Although this projector sets proper signal systems
automatically for the image signal from personal
computers, it cannot be applied to some of personal
computers. In this case, press the AUTO POSITION
button. If the images are still not projected correctly,
use the MENU display to adjust the projected im-
ages.

Image moved to right or left :
Adjust HORIZ. POSITION in SIGNAL menu. Press
the

% button to move the image to left. Press the $

button to move the image to right.

Image moved to up or down :
Adjust VERT. POSITION in SIGNAL menu. Press
the

% button to move the image to upward. Press

the

$ button to move the image to down.

Image flickers / Image is out of focus :
Adjust FINE SYNC. in SIGNAL menu.

Wide stripes appear :
Adjust CLAMP POSITION or CLAMP WIDTH of
each menu in SIGNAL - USER menu.

Noise etc. appears on right or left side of image :
Adjust HORIZ. PIXELS of the menu in SIGNAL -
USER menu.

Noise etc. appears on top or bottom part of image :
Adjust SHUTTER (U), SHUTTER (L) or VERT.
LINES of the menu in SIGNAL - USER menu.

MEMORY CALL

SIGNAL

AUTO

HORIZ. POSITION

208

VERT. POSITION

22

TRACKING

1056

COMPUTER INPUT

RGB

FINE SYNC.

24

HOLD

AUTO

USER

MEMORIZE

DELETE

DEFAULT

R G B

R G B

A

U

Opt

XGA60

CLAMP POSITION

SIGNAL–USER

0

CLAMP WIDTH

+ 5

HORIZ. PIXELS

800

PLL

AUTO

SHUTTER(L)

0

VERT. LINES

600

VERT. SYNC.

AUTO

SHUTTER(U)

0

?

Top part of image curves :
Change the setting of HOLD in SIGNAL menu or
PLL in SIGNAL - USER menu.

HOLD ... Select ON, and adjust BEGIN or
END for image which top part is the
least curved.
PLL ....... Select FAST, NORMAL, or SLOW for an
image in which top part is the least
curved. Select AUTO for normal setting.

Image does not move naturally :
Adjust VERT. SYNC. of the menu in SIGNAL -
USER menu. Select AUTO for normal setting.
curved. Select AUTO for normal setting.

Do not change each menu setting in USER
menu for normal setting.

Simple adjustment method
1. Select HORIZ. POSITION in SIGNAL menu.

2. Press the

$ or % button to adjust the horizontal

start position (the left end).

3. Select TRACKING in SIGNAL menu.

4. Press the

$ or % button to adjust the horizontal

end position (the right end).

5. Repeat steps 1 to 4 for fine adjustment.

6. Select VERT. POSITION in SIGNAL menu.

7. Press the

$ or % button to adjust the vertical

start position (the top end).

Advertising
This manual is related to the following products:

X70