Inditherm, With high temperature discharge sleeve - all sizes – Maxon Telecom INDITHERM 300 User Manual

Page 8

Advertising
background image

Low temperature burners - INDITHERM

®

w w w . m a x o n c o r p . c o m

combustion systems for industry

MAXON reserves the right to alter specifications and data without prior notice.
© 2008 Copyright Maxon Corporation. All rights reserved.

1 - 2.3 - 13
E - m - 7/08

INDITHERM

®

with high temperature discharge sleeve - all sizes

[1] Gas inlet is threaded, available in ISO or NPT.

1)

Gas inlet

2)

Pilot gas connection

3)

Combustion air test connec-
tion

4)

Gas pressure test connec-
tion

5)

90° capacity control crank

6)

Filter housing (optional)

7)

High temperature discharge
sleeve

8)

Flame supervision port

9)

Spark ignitor

Dimensions in mm unless stated otherwise

burner size gas inlet

[1]

A

B

C

ØD

E

F

G

H

I

J

K

L

ØM ШN Ш P

S

Weight (kg)

100

1”

365

232 200 257 111 442 100 397 438 224 289 353 320 357

14

12

47

300

1 1/4”

365

231 200 305 111 442

98

397 438 224 289 353 368 405

14

12

57

550

1 1/2”

514

259 200 357 138 541 104 439 466 308 367 400 420 457

14

12

83

700

2”

598

259 200 357 138 786

75

439 504 387 403 448 420 457

14

12

83

850

2”

598

259 200 357 138 777

75

469 502 387 403 448 420 457

14

12

83

1100

2”

597

369 200 408 165 777 140 564 597 387 403 448 471 508

14

12

110

1500

2”

597

369 200 408 165 777 140 564 597 387 403 448 471 508

14

12

110

1800

3”

659

369 200 408 165 809 140 609 667 451 452 480 471 508

14

12

110

1

8

6

5

7

9

4

2

3