Performance data, Continued), Power is in the numbers – Miller Electric Trailblazer Pro 350 D User Manual
Page 3
3
VOLT/AMP CURVES
MINIMUM AND MAXIMUM - STICK MODE
AMPERES
VOL
TS
0
10
20
30
40
50
60
70
80
0
100
200
300
400
500
600
DUTY CYCLE CHART
WELD AMPERES
% DUTY CYCLE
0
10
20
30
40
50
60
70
80
90
100
100
150
200
250
300
350
400
DC Weld
AC Weld
VOLT/AMP CURVES
MINIMUM AND MAXIMUM - MIG MODE
AMPERES
0
100
200
300
400
500
600
0
10
20
30
40
50
60
70
80
VOL
TS
GENERATOR POWER CURVE
AC VOL
TS
AC AMPERES IN 240V MODE
AC AMPERES IN 120V MODE
300
250
200
150
100
50
0
150
125
100
75
50
25
0
0
10
20
30
40
50
60
70
80
90
0
20
40
60
80
100
120
140
160
180
SIMULTANEOUS WELDING
AND GENERATOR POWER
Weld
Current
(Amps)
Watts
120V 1P
Receptacle
Amps
240V 1P
Receptacle
Amps
0
100
150
200
300
350
100
90
80
62
25
10
50
45
40
31
12
5
12,000
11,000
9,500
7,500
3,000
1,000
12 kW
Performance Data
(continued)
All Trailblazers have 2 generators —
a 4-pole, 3-phase weld generator and a
strong power generator.
TRAILBLAZER ADVANTAGE: No interaction
between grinders, power tools, etc. and
the welding arc. Generator power is also
independent of weld control settings.
POWER IS IN THE NUMBERS
•
Tested and rated at higher temperatures, 104˚ F (40˚ C), to ensure consistent operation in all climates.
•
Patented generator control technology matches the generator’s output to engine horsepower providing maximum efficiency
and more weld output.
•
The generator is voltage regulated to provide strong power while keeping the voltage 120/240 volts. This increases
tool/motor performance and tool/motor life.
Stator
Rotor