M2d specifications – Meyer Sound M2D User Manual

Page 4

Advertising
background image

M2D specifications

1. The low-frequency power response

of the system will increase according
to the length of the array.

2. Recommended maximum operating

frequency range. Response depends
on loading conditions and room
acoustics.

3. Free field, measured with 1/3 octave

frequency resolution at 4 meters.

4. Measured with music at 1 meter.
5. At this frequency, the mid- and

high-frequency transducers produce
equal sound pressure levels.

6. Power handling is measured under

AES standard conditions: transducer
driven continuously for two hours
with band-limited noise signal
having a 6 dB peak-average ratio.

7. To eliminate interference at short

wavelengths, the two 10-inch cone
drivers work in combination at low
frequencies (60 Hz – 350 Hz). At
mid frequencies (350 Hz – 575 Hz)
only one cone driver is fed from
the crossover to maintain optimal
polar and frequency response
characteristics.

8. The driver is coupled to a

constant-directivity horn through
a proprietary acoustical manifold
(REM).

9. Amplifier wattage rating based on

the maximum unclipped burst sine-
wave rms voltage that the amplifier
will produce into the nominal load
impedance. Low channel 30 V rms
(42 V pk) into 2 ohms; high channel
32 V rms (45 V pk) into 8 ohms.

10. No automatic turn-off voltages.

Voltages above 265 V AC are fuse
protected but may cause permanent
damage to the power supply.
Voltages below 90 V AC may result in
intermittent operation.

meyer sound laboratories inc.
2832 San Pablo Avenue
Berkeley, CA 94702

T: +1 510 486.1166
F: +1 510 486.8356

[email protected]
www.meyersound.com

M2D - 04.112.011.01 B

Copyright © 2004
Meyer Sound Laboratories Inc.
All rights reserved

Operating Frequency Range

2

Frequency Response

3

Phase Response

Maximum Peak SPL

4

Dynamic Range

Horizontal Coverage

Vertical Coverage

Low/Mid Frequency

7

High Frequency

8

Type

Maximum Common Mode Range

Connectors

Input Impedance

Wiring

DC Blocking

CMRR

RF Filter

TIM Filter

Nominal Input Sensitivity

Input Level

Type

Output Power

THD, IM, TIM

Load Capacity

Cooling

Connector

Voltage Selection

Safety Agency Rated Operating Range

Turn-on and Turn-off Points

10

Current Draw:

Idle Current

Max Long-Term Continuous Current (>10 sec)

Burst Current (<1 sec)

Ultimate Short-Term Peak Current Draw

Inrush Current

60 Hz - 16 kHz
70 Hz - 14 kHz ±4 dB
650 Hz - 12 kHz ±45°
136 dB
>110 dB

90°
Varies, depending on array length and configuration

575 Hz

5

Two 10" cone drivers with neodymium magnets
Nominal impedance: 4

Voice coil size: 2"
Power-handling capability: 400 W (AES)

6

One 4" compression driver
Nominal impedance: 8

Voice coil size: 4"
Diaphragm size: 4"
Exit size: 1.5"
Power-handling capability: 250 W (AES)

6

Differential, electronically balanced
±15 V DC, clamped to earth for voltage transient protection
Female XLR input with male XLR loop outputor VEAM all-in-one
connector (integrates AC, audio and network)
10 k

differential between pins 2 and 3

Pin 1: Chassis/earth through 220 k

, 1000 pF, 15 V clamp network

to provide virtual ground lift at audiofrequencies
Pin 2: Signal +
Pin 3: Signal -
Case: Earth ground and chassis
Differential DC blocking up to max common mode voltage
>50 dB, typically 80 dB (50 Hz - 500 Hz)
Common mode: 425 kHz
Differential mode: 142 kHz
Integral to signal processing (<80 kHz)
0 dBV (1 V rms, 1.4 V pk) continuous average is typically the onset
of limiting for pink noise and music
Audio source must be capable of producing a minimum of +20 dBV
(10 V rms, 14 V pk) into 600

inorder to produce maximum peak

SPL over the operating bandwidth of the loudspeaker

Two-channel complementary MOSFET output stages (class AB/
bridged)
700 W

9

<.02 %
2

low channel, 8

high channel

Convection; 24 V DC output for optional external fan

PowerCon or VEAM
Automatic
100 V AC - 240 V AC; 50/60 Hz
Continuous 90 V AC - 265 V AC; 50/60 Hz

0.35 A rms (115 V AC); 0.35 A rms (230 V AC); 0.35 A rms (100 V AC)
3.1 A rms (115 V AC); 1.6 A rms (230 V AC); 3.6 A rms (100 V AC)
3.2 A rms (115 V AC); 1.6 A rms (230 V AC); 3.7 A rms (100 V AC)
5.8 A pk (115 V AC); 2.9 A pk (230 V AC); 6.7 A pk (100 V AC)
9 A pk (115 V AC and 230 V AC); 8 A pk (100 V AC)

Equipped for two conductor twisted-pair network, reporting all
operating parameters ofamplifiers to system operator’s host
computer.

Notes:

Acoustical

1

Coverage

Crossover

Transducers

Audio Input

Amplifier

AC Power

RMS Network

Advertising