TLW-300SS — CONTROLS AND INDICATORS

Figure 5 shows the location of the controls and indicators. The
functions of each control or indicator is described below.

1.

Voltage Regulator- Controls the Voltage for welding/load.

2.

AC Voltmeter- Indicated amount of voltage output.

3.

Main Circuit Breaker- 2-pole, 42A will shut down current
when welder/generator is overloaded.

4.

No. 1 Circuit Breaker-(S/N 5308737~)- single pole circuit
breaker will shut down current in the 240V/30A receptacle.

5.

Ignition Switch with Key- Used to start and preheat engine.

6.

Engine Warning Indicators- Lights red when the following
conditions occur:

7.

Hour Meter – Indicates number of hours machine has
been in use or hours engine was run.

8.

Idle Switch- Turn on for rpms to automatically adjust rpms
when a load is added.

9.

No. 3 Circuit Breaker-(S/N 5308737~)- single pole circuit
breaker will shut down current in the 120V/20A receptacle.

10. No. 2 Circuit Breaker-(S/N 5308737~)- single pole circuit

breaker will shut down current in the 120V/30A receptacle.

11. Positive Welding Output Terminal- Positive connection

for welding.

12. Negative Welding Output Terminal-Negative connection

for welding.

13. G.F.C.I. Ground Terminal- Used to ground GFCI

receptacle.

14. G.F.C.I. Receptacle- 120V/20A receptacle for smaller

power applications.

15. 120V Receptacles- used for 20 or 30 amp power

applications.

16. 240V Receptacle- used for 30 amp power applications.

 Low Oil Pressure
 High Water Temperature
 Electrical System Is Not Charging Properly