Dcm100 user’s manual – Maretron DCM100 User Manual

Page 24

Advertising
background image

DCM100 User’s Manual

Page A2

Appendix A – NMEA 2000 Interfacing

Revision 1.0

PGN 127508 – Battery Configuration Status
The DCM100 uses this PGN to transmit unchanging battery configuration data.

Field 1: Battery Instance – This field indicates the particular battery for which this data

applies. A single battery will have an instance of 0. Batteries in boats with multiple
batteries will be numbered uniquely, starting at 0.

2: Battery Type – This field indicates the type of battery. The DCM100 indicates one of

the following values: 0=Flooded, 1=Gel, 2=AGM.

3:

Supports

Equalization

This field indicates whether the battery supports an

equalization charge. The DCM will always transmit a value of 0 for this field.

4: Reserved – This field is reserved by NMEA; therefore, the DCM100 sets all bits to a

logic 1.

5: Nominal Voltage – This field indicates the nominal voltage of the battery. The

DCM100 indicates one of the following values: 0=6 Volts, 1=12 Volts, 2=24 Volts,
3=32 Volts, 4=36 Volts, 5=42 Volts, 6=48 Volts.

6: Battery Chemistry – This field indicates the chemistry of the battery. The DCM100

indicates one of the following values: 0=Lead Acid, 1=LiIon, 2=NiCad, 3=ZnO,
3=NiMH.

7: Battery Capacity – This field indicates the capacity of the battery in units of 1 amp-

hour.

8: Battery Temperature Coefficient – This field indicates the increase of battery capacity

with increasing temperature in units of 1%/°C.

9: Peukert Exponent – This field indicates the Peukert exponent of the battery with a

resolution of 0.002 (unitless).

10: Charge Efficiency Factor – This field indicates the charge efficiency factor of the

battery in units of 1%.

Advertising