TROUBLESHOOTING

TROUBLESHOOTING

Before determining any specific cause of a breakdown or abnormal operation of your
glasswasher, check that:

1.

All switches are ON.

2.

Wash arms are clean.

3.

Scrap screen is properly positioned and clean.

4.

Thermostat(s) are at their correct setting.

5.

Sanitizer, detergent, and rinse additive dispensers are adequately filled.

6.

All plumbing valves are open.

If a problem still exists, use the following table for troubleshooting.

CONDITION

CAUSE

SOLUTION

Machine will not start

Door not closed ..................................

Make sure door is fully closed

Main switch off, or unit unplugged ....

Check disconnect or plug into outlet

Low or no water

Main water supply is turned off .........

Turn on house water supply

Chemical not feeding

No chemical in container.....................

Replace or fill container

Feed tubes to/from chemical ...............

Clear obstruction and flush

pump clogged

with hot water

Screen on feed tube clogged................

Clean and replace

Tubing kinked or split .........................

Straighten or replace tubing

Water temperature

Incoming water temperature................

Raise temperature to

is low when in use

at machine too low

60°C/140°F for all machines

Insufficient pumped spray

Clogged spray arm ..............................

Clean

pressure

Scrap screen full ..................................

Must be kept clean and in place

Poor washing results

Detergent dispenser not.......................

Contact service agent

operating properly
Insufficient detergents .........................

Check and fill
Contact detergent supplier

Detergent setting too low ...................

Contact detergent supplier

Wash water temperature too low.........

Check incoming water temp

Wash arm clogged ..............................

Clean wash arm

Improperly scrapped glasses ...............

Check scrapping procedures

Ware being improperly........................

Use proper racks - do not overload

placed in rack

racks

Improperly cleaned .............................

Unclog wash arms to maintain

equipment

proper pressure and flow conditions

Electric element has ............................

Clean and delime

soil/lime buildup

Machine overflows on

Wash pump impeller ...........................

Remove pump assembly and clean impeller

to floor

plugged with trash