generator storage

For storage of the generating set for over 30 days, the

following is required:

„

Drain the fuel tank completely, or add STA-BIL to the

fuel.

„

Run the engine until the gasoline in the carburetor is

completely consumed.

„

Completely drain the oil from the crankcase and refill

with fresh oil.

„

Remove the spark plug, pour 2 or 3 cc of SAE 30 oil into

the cylinder and crank slowly to distribute the oil.

„

Slowly rotate the engine a few times with the starter rope

and install a new plug.

„

Pull out the starter rope slowly and stop at the

compression point.

„

Clean all external parts of the generating set with a

cloth.

„

Cover the generating set and store in a clean, dry

place.