Connect to the network, 6installation guide – METRObility Optical Systems 3508-11 User Manual

Page 6

Advertising
background image

6

Installation Guide

Connect to the Network

The Lancast CenturySwitch is compatible with both 10Base-T and
100Base-TX devices. Network connections are made by simply plugging
the cables into the RJ-45 port connectors on the front panel as shown in
the figure below. Each port supports a maximum segment length of 100
meters over Category 5 UTP cables for 100Base-TX segments and
Category 3, 4 or 5 UTP cables for 10-Base-T segments. Once power is
applied to the unit, use the individual Link/Act LEDs to verify correct
segment connectivity.

3

Fixed Ports
The CenturySwitch provides seven fixed RJ-45 ports with connectors for
devices wired crossover. The ports are labeled 1x through 7x. These dual-
speed ports are 10/100Mbps auto-sensing and will automatically detect
and operate at the speed of the connected device.

Module Port
Port 8 provides two RJ-45 connectors which support a device wired either
crossover (MDI-X) or parallel (MDI-II).

IMPORTANT: Do not connect devices to both the MDI-X and MDI-II
connectors at the same time. This can damage the unit and void its
warranty.

CenturySwitch

®

3508-11

FDX

Link/Act

100Mbps

Power

Module Port 8

1 2 3 4 5 6

7 8

1x

2x

3x

4x

5x

6x

10/100 Ethernet Switch

7x

MDI-X

MDI-II

®